Biomechanics of Rehabilitating
the Perioprosthetic Patient
91
[103]
Tan K, Pjetursson BE, Lang NP, Chan ES. A systematic review of the survival and
complication rates of fixed partial dentures (FPDs) after an observation period of at
least 5 years.
Clin. Oral Implants Res.
2004;15:654-66.
[104]
Pjetursson BE, Tan K, Lang NP, Brägger U,Egger M, Zwahlen M. A systematic review
of the survival and complication rates of fixed partial dentures (FPDs) after an
observation period of at least 5 years.
Clin. Oral Implants Res
. 2004;15:667-76.
[105]
Lundgren D. Prosthetic reconstruction of dentitions seriously compromised by
periodontal disease.
J. Clin. Periodontol
. 1991;18:390-5.
[106]
Karlsson S. Failures and length of service in fixed prosthodontics after long-term
function. Alongitudinal study.
Swed. Dent. J
. 1989;13:185-92.
[107]
Kourkouta S, Hemmings KW, Laurell L. Restoration of periodontally compromised
dentitions using cross-arch bridges. Principles of perio-prosthetic patient management.
Br. Dent. J
. 2007;203:189-95.
[108]
Manda M, Galanis C, Georgiopoulos V, Provatidis C, Koidis P. Effect of
severely
reduced bone support on the stress field developed within the connectors of three types
of cross-arch fixed partial dentures.
J. Prosthet. Dent.
2009;101:54-65.
[109]
Erhardson S, Carlsson J, Wictorin L. Fracture mechanics design of dental soldered
joints.
Swed. Dent. J. Suppl
. 1980;1-62.
[110]
Lundgren D, Laurell L. Occlusal force pattern during chewing and biting in dentitions
restored with fixed bridges of cross-arch extension. II. Unilateral posterior
two-unit
cantilevers.
J. Oral Rehabil.
1986;13:191-203.
[111]
Hanihara T, Ishida H. Metric dental variation of major human populations.
Am. J. Phys.
Anthropol.
2005;128:287-98.
[112]
Craig RG. Advances in biomaterials from 1957 to 1997.
J. Oral Rehabil.
1999;26:841-
6.
[113]
Oh WS, Anusavice KJ. Effect of connector design on the fracture resistance of all-
ceramic fixed partial dentures.
J. Prosthet. Dent.
2002;87:536-42.
[114]
Oh W, Götzen N, Anusavice KJ. Influence of connector design on fracture probability
of ceramic fixed-partial dentures.
J. Dent. Res.
2002;81:623-7.
[115]
Rodriguez AM, Aquilino SA, Lund PS. Cantilever and implant biomechanics: a review
of the literature. Part 1.
J. Prosthodont
. 1994;3:41-6.
[116]
Schweitzer JM, Schweitzer RD, Schweitzer J. Free-end pontics used on fixed partial
dentures.
J. Prosthet Dent.
1968;20:120-38.
[117]
Glantz PO, Nyman S, Strandman E, Randow K. On functional strain
in fixed manibular
reconstructions. II. An in vivo study.
Acta Odontol. Scand
. 1984;42:269-76.
[118]
Awadalla HA, Azarbal M, Ismail YH, el-Ibiari W. Three dimensional finite element
stress analysis of a cantilevered fixed partial enture.
J. Prosthet Dent.
1992;68:243-8.
[119]
Yang HS, Chung HJ, Park YJ. Stress analysis of a cantilevered fixed partial denture
with normal and reduced bone support.
J. Prosthet Dent
. 1996;76:424-30.
[120]
Wang CH, Lee HE, Wang CC, Chang HP. Methods
to improve a periodontally
involved terminal abutment of a cantilevered fixed partial denture--a finite element
stress analysis.
J. Oral Rehabil.
1998;25:253-7.
[121]
Yang HS, Lang LA, Felton DA. Finite element stress analysis on the effect of splinting
in fixed partial dentures.
J. Prosthet Dent.
1999;81:721-8.
Petros Koidis and Manda Marianthi
92
[122]
Eraslan O, Sevimay M, Usumez A, Eskitascioglu G. Effects of
cantilever design and
material on stress distribution in fixed partial dentures--a finite element analysis.
J.
Oral Rehabil
. 2005;32:273-8.
[123]
Augereau D, Pierrisnard L, Barquins M. Relevance of the finite element method to
optimize fixed partial denture design. Part I. Influence of the size of the connector on
the magnitude of strain.
Clin. Oral Investig.
1998;2:36-9.
[124]
Motta AB, Pereira LC, da Cunha AR, Duda FP. The influence of the loading mode on
the stress distribution on the connector region of metal-ceramic and all-ceramic fixed
Dostları ilə paylaş: