3. Report Pilot Action fua milan



Yüklə 0,83 Mb.
Pdf görüntüsü
tarix05.10.2018
ölçüsü0,83 Mb.
#72138


 

 

 



 

Page 1 


 

 

 



 

 

 



 

 

 



 

 

 



 

Pilot Action: Milan Functional Urban Area 

Version 1

03 2017

D.T 2.3.4 




 

 

 



 

Page 2 


 

1.

 

Pilot Action Milan FUA

 

Milan  FUA  is  one  of  the  most  densely  populated  areas  in  Lombardy  (northern  Italy).  In 

particular,  in  the  FUA  of  Milan  about  2.254.263  inhabitants  live  within  521  km

2

.  The 



northern  area  of  FUA  is  characterised  by  a  dense  agglomeration  of  companies,  and 

especially  near  the  Milano  City  historically  (from  ’50)  are  located  many  industries  such 

as  automotive,  refineries,  chemical  plants,  still  and  tires  production.  Because  of  the 

high  hydraulic  conductivity  and  the  high  groundwater  withdrawal  rate  (public 

withdrawal  is  within  8000  l/s),  Milan  represents  a  drainage  area  of  groundwater  and 

many pollutants flows into municipality. 

Especially  the  north-west  area  of  Milan  has  since  ’70  a  direct  effect  on  water  quality 

near  water  supply  wells  at  pumping  station  in  Milan.  Thus,  the  area  is  hit  by  several 

plumes,  which  deteriorate  groundwater  quality  over  decades.  It  is  very  important  to 

evaluate  the  extension  of  the  plumes  and  distinguish  areas  within  the  FUA  where 

concentration values exceed the national threshold values. 

 

 



a)

 

 



b)

 

 



Figure 1 - a) satellite view of the area of pilot action, b) GIS representation of the area 

of interst: pilot action in violet and in yellow the FUA of Milan. 

 

In Figure 1 are represented respectively a satellite view of the pilot area (a) and a GIS 



schematization  of  the  pilot  area  and  the  Milan  FUA.  As  it  is  showed  in  figure  1  a)  the 

area is very densely anthropized and, consequently, populated. 

Nowadays, the pilot action (about 12 municipalities within the violet coloured area with 

617.773  inhabitants)  is  densely  populated,  and  especially  near  the  northern  border  of 

Milan  it  is  heavily  industrialised.  More  than  34  contaminated  sites  are  located  in  this 



 

 

 



 

Page 3 


 

zone. Of these about 10 are known or suspected to discharge chlorinated solvents in the 

groundwater.  Many  plumes  involve/affect/include  both  shallow  and  deep  aquifer.  It 

became  important  to  distinguish  in  this  area  the  contribution  of  these  plumes  and  the 

diffuse contamination that afflicts the groundwater bodies.  

A  lot  of  single  site  investigation  and  remediation  took  place  in  the  area  in  the  last 

decades. Additional field studies (hydrogeological and numerical model) were developed 

within  PLUMES  PROJECT  (ARPA  for  Lombardy  Region)  in  order  to  identify  hotspots 

responsible  of  the  plumes.  Considering  all  monitoring  wells  hit  by  plumes,  a 

geostatistical  analysis  was  performed  in  order  to  have/define/calculate  a  preliminary 

value  of  diffuse  contamination.  In  the  pilot  area  many  groundwater  wells  are  built  in 

different aquifers, see Figure 2.  

 

Figure 2 Representation of the groundwater monitoring wells in the pilot area: in violet 



the  deep  wells/piezometers,  in  blue  the  shallow  wells/piezometers  and  in  green  the 

new piezometers that will be realized within AMIIGA project. 




 

 

 



 

Page 4 


 

 

Figure 3 shows the geological build-up through the project area. An aquitard (thickness 



of 10 meters of low permeability) divides a shallow aquifer with a sand gravel material 

with a relative high hydraulic conductivity from a deep aquifer, which is constituted by 

fine sand. The separation of two aquifers becomes more and more discontinuous in the 

norther part of Milan.  

 

Figure 3 Geological build-up with the delineation of the FUA aquifers. 



 

Because  of  this  hydrogeological  conformation,  many  plumes  in  the  northern 

municipalities  can  flow  from  shallow  to  deeper  aquifers  causing  pollution  in  deeper 

wells. In Figure 4, the Tetrachloroethylene concentrations monitored from 2003 to 2014 

are  represented.  While  the  higher  values  (red  colour-brown  colour)  could  be 

representative  of  hotspot  contamination  and  associated  to  possible  plumes  extension, 

the  values  within  10 

µ

g/l  could  be  linked  to  diffuse  contamination.  In  the  next  step, 



strategies and methodologies to handle the diffuse contamination and the contamination 

plumes will be developed within the AMIIGA project.  

 

N

 

S

 

SAND-GRAVEL (K=10

-3

 m/s)

 

FINE SAND (K=10



-5

 m/s)

 



 

 

 



 

Page 5 


 

 

Figure 4 Tetrachloroethylene monitoring wells/piezometers – from 2003 to 2014.  



 

The following activities are planned in FUA Milan: 



×

 

Hydrogeological  and  groundwater  monitoring  data  collection  (hydraulic  and 

contaminant  characterization  for  shallow  and  deep  aquifer  available  until  2016)  is 

being updated.  



×

 

Hydro-geological  and  numerical  models  will  be  updated  in  order  to  improve  the 

results of plume extension in pilot area. 

×

 

Six  monitoring  wells  in  the  deep  aquifer  will  be  drilled  to  optimize  the  existing 

groundwater  monitoring  network  in  order  to  distinguish  plumes  and  diffuse 

contamination  area  (Four  groundwater  monitoring  wells  in  the  shallow  aquifers  and 

two groundwater, see Figure 2). 



 

 

 



 

Page 6 


 

×

 

The Regional Implementation Group, that will be involved in the preparation of the 

Groundwater Management plan for the FUA, will officially meet for the first time the 

19 of April. 



×

 

Three  sampling  campaigns  will  be  done  in  order  to  survey  the  extension  of  plumes 

(PCE,  TCE,  TCM,  cis-DCE,  vinyl  chloride,  methane,  sulphates,  iron  cations, 

manganese,  nitrates,  dissolved  oxygen)  and  support  their  numerical  transport 

modelling.  The  CSIA  analyses  will  be  useful  to  distinguish  plumes  from  a  diffuse 

contamination in the pilot area. 