Chapter 5: Building and Adjusting Structures
Schrödinger Software Release 2015-2
108
4. When the desired point group is found, click
Symmetrize
.
Structures that are built by drawing, or have been adjusted manually, can be far from the
minimum energy structure. To “clean up” the structure in the Workspace, the Geometry
Cleanup utility minimizes the energy of the structure or of the selected atoms using either the
built-in minimizer with the OPLS_2005 force field, or the Universal Force Field (UFF). The
choice of minimizer and force field can be set either from the
Clean Up
button menu or in the
Preferences
panel (see
Section 14.12 on page 371
).
Cleanup realigns atoms that are too crowded and corrects unphysical geometries.
In general, it
corrects distortions that can cause jobs to fail, such as MacroModel or Jaguar jobs. Minimiza-
tion proceeds for 300 cycles or until the maximum atom displacement is less than 0.05 Å. By
default, when using the built-in minimizer, atoms within 5 Å of the selected atoms are
restrained with a moderate restraint, and atoms within 5 Å of these atoms are restrained with a
much tighter restraint. The rest of the atoms are frozen, but you can set a preference to freeze
all unselected atoms—see
Section 14.12 on page 371
.
To run this utility, choose
Edit
→
Build
→
Clean Up Geometry
, press
U
, or click the
Clean Up
button on the
Build
toolbar. This job is not run at reduced priority, unlike most local jobs.
You can also use the built-in minimizer on the
selected atoms by choosing
Tools
→
Minimize
→
Selected Atoms
or pressing
CTRL+M
(
M
), which minimizes for 1000 cycles or a
maximum displacement of 0.01 Å. If no atoms are selected, all atoms are minimized. To mini-
mize the ligand, choose
Tools
→
Minimize
→
Ligand
or press
CTRL+SHIFT+M
(
M
).
5.10 Adding and Treating Hydrogen Atoms
When building molecules or preparing proteins, you might want to apply a hydrogen treatment
that is compatible with the force field you intend to use in calculations on those structures. You
can also use a hydrogen treatment to add hydrogen atoms to a structure that is used for any
program that requires explicit hydrogen atoms, such as QikProp or Jaguar. Hydrogen treat-
ments can treat hydrogen atoms explicitly or implicitly, as part of another atom. To select and
apply a hydrogen treatment, you can use the controls in the
Add Hydrogens - Advanced
panel,
which you open by choosing
Edit
→
Add Hydrogens
→
Advanced
.
Chapter 5: Building and Adjusting Structures
Maestro 10.2 User Manual
109
Figure 5.11. The Add Hydrogens - Advanced panel.
To select a hydrogen treatment, choose an option from the
Treatment
option menu. A descrip-
tion of the treatment is displayed in the
Description
text box, including the force fields for
which the treatment is valid. This information is also given in
Table 5.2
.
You can apply the selected treatment to the entire structure or to selected parts of the structure.
To apply the treatment to the entire structure click
All
in the
Modify Hydrogen Treatment
section. To apply the treatment to selected atoms, use the picking tools in the
Modify Hydrogen
Treatment
section or click
Select
to open the
Atom Selection
dialog box and define the selected
atoms. If the structure already complies with the treatment you selected, no changes will be
made when you apply the treatment.
You can also apply the current hydrogen treatment to selected atoms, molecules, residues,
chains, or entries from the main toolbar or the
Build
panel toolbar. Select one of these structural
units from the
Add H
button menu,
then pick atoms in the Workspace to apply the treatment. Double-click this button to apply the
treatment to all atoms in the Workspace.
Each time you select a force field in the
Potential
section of a MacroModel or Impact energy
panel, the hydrogen treatment is automatically changed to comply with that force field, and the
hydrogen treatment for any atoms you subsequently draw in the Workspace will have the new
hydrogen treatment. If you attempt to start a MacroModel, Impact, or Jaguar job using an input
structure with an incompatible hydrogen treatment, the job fails.
Chapter 5: Building and Adjusting Structures
Schrödinger Software Release 2015-2
110
5.11 Changing Atom Properties
In addition to changing the element and the formal charge, you can change a variety of other
atom properties. The tools for making changes are in the
Atom Properties
tab. Each choice of
property from the
Property
option menu displays a set of tools that you can use to change the
property. Apart from the
Element
property, the properties are listed below with a description of
the tools. The last item on the option menu,
Other
, allows you to change the values for any
other atom property.
Before you change atom properties, it may be helpful to display atom labels. For atom labeling
information, see
Section 8.2 on page 162
.
5.11.1
Atom type (MacroModel)
When you choose
Atom type (MacroModel)
from the
Property
option menu, a list of atom type
symbols with a brief description is displayed (see
Figure 5.12
). The atom type symbols repre-
sent atoms with specific properties, such as sp
3
hybridization for a C atom with type symbol
C3, or a free radical for a C atom with type symbol CR. To retype an atom,
choose the atom
type and click on the atoms in the Workspace that you want to change.
The use of atom types is provided primarily for MacroModel users, though Maestro always
assigns an atom type to each atom. For information on atom types, see
Appendix B
.
Table 5.2. Appropriate hydrogen treatments for Maestro-supported force fields.
Hydrogen Treatment
Method
MM
3
MM
2
AMBER
AMBER94
MM
FF
MM
FFS
OPLS-AA,
OPLS_20
0x
OPL
S
All-atom with No-Lp
X
X
X
X
X
X
All-atom with Osp3-Lp
X
Csp3 United-atom with
S-Lp
a
X
Csp3 United-atom with
No-Lp
a
X
All atom with S-Lp
X
Csp2/sp3 United atom
with No-Lp
a
X
a. In a united atom representation, hydrogen atoms are incorporated into the dimensions of the heavy
atom to which they are attached. That is, they are implicit.