Chapter 2  
|
  
Meter Basics 
Icon 
Name 
Description 
 
USB Icon 
Shown when the Communication option is set to USB or USB 
PRINTER in the Instrument Settings setup menu. 
 
RS232 Icon 
Shown when the Communication option is set to RS232 in the 
Instrument Settings setup menu. 
  Auto-Read Icon 
Shown when the measurement read type is set to Auto-Read. The icon 
flashes while the measurement value is stabilizing and remains sold 
when the measurement value is stable and locked on the display. 
  Timed Read Icon  Shown when the measurement read type is set to Timed. 
  Single-Shot Icon  Shown when the measurement read type is set to Single-Shot. 
Stabilizing 
Stability Indicator  Flashes while the measurement value is stabilizing. 
Ready 
Stability Indicator  Shown when the measurement value is stable. 
 
Cal Due Alarm 
Flashes when the calibration due alarm is triggered. Cal Due Alarm 
must be enabled in the channel-specific setup menu. 
 
User ID Icon 
Shown with the user name or label entered for the active method. To 
be shown, User ID must be selected in the Display View setting in the 
Instrument Settings setup menu and a protected method must be 
loaded on the displayed channel.  
 
Electrode ID Icon  Shown with the electrode serial number, name or label entered using a 
channel-specific setup menu.  
 
Sample ID Icon 
Shown with the auto-incremental sample value or sample name or 
label entered using a channel-specific setup menu or Sample ID 
shortcut key. 
 
pH Electrode Condition Icon 
V
ERSA 
S
TAR
 meters with pH, pH/ISE and pH/LogR modules include a pH electrode condition 
icon. In the measurement mode, the electrode condition icon indicates the performance of the 
electrode, based on the last saved calibration and electrode measurement stability. 
Icon 
pH Electrode Status 
 
Electrode condition is good. 
The electrode slope is in the range of 95.1% to 104.9 %. 
 
Electrode condition is fair. 
The electrode slope is in the range of 85.1% to 114.9%. 
 
Electrode condition is bad.  
The electrode slope is less than 85% or greater than 115%.  
Consult the pH electrode user manual for instructions on how to clean, condition and 
troubleshoot the electrode. 
 
 
 
20  
|
  
Orion V
ERSA 
S
TAR
 Meter User Manual 
Thermo Scientific 


Chapter 2  
|
  
Meter Basics 
Customizing the Display  
The information shown in the measurement mode can be customized. Reducing the information 
will increase the font size of the main measurement value in the single channel display. 
1.
 
In the measurement mode, press the setup key. 
2.
 
Press the ►key until Instrument Settings is highlighted and press the f3 (Select) key.  
3.
 
Display will be highlighted in the left column. Press the  key to also highlight Display 
View and press the f3 (Select) key. 
4.
 
Press the  or ▼ key to highlight an item and press the f3 (Select) key to check (display) 
or uncheck (hide) the item. Some items will only be shown in the single channel display 
when checked. 
 
5.
 
Press the f1 (Done) key and then press the measure (esc) key to return to the 
measurement mode.   
 
 
Example measurement display with all  
information shown 
Example measurement display with limited 
information shown 
 
Meter and Module Maintenance 
·
 
For routine meter and module maintenance, dust and wipe with a damp cloth. If necessary, 
warm water or mild water-based detergent can be used.  
·
 
Meter maintenance can be performed on a daily, weekly or monthly basis, as required by 
the operating environment.  
·
 
Remove any spilled substances immediately from the meter or module using the proper 
cleaning procedure for that spill type. 
Thermo Scientific 
Orion V
ERSA 
S
TAR
 Meter User Manual  
|
  
21
 


 

Meter Setup Menus  
Main Setup Menu 
 
The Main Setup menu
 
of the
 
V
ERSA 
S
TAR
 meter organizes the menus for channel-specific 
measurement settings, instrument settings, calibration and data log, and meter diagnostics in 
one easy to access location. This allows quick and easy navigation to view or change 
measurement and instrument settings, view calibration and data history, and perform a meter 
self test or view meter and module serial number and software revisions.   
Since the V
ERSA 
S
TAR
 meter offers four channels that can be configured in any combination, 
one to four channel-specific setup menus will be shown in the Main Setup menu, depending on 
the number of measurement modules that are actively connected to the meter.  
1.
 
In the measurement mode, press the setup key to access the Main Setup menu.  
2.
 
Press the  or  key to highlight a setup menu from the list and press the f3 (Select) key 
to access the submenus and parameters for the selected setup menu.  
 
C H A P T E R   3  
22  
|
  
Orion V
ERSA 
S
TAR
 Meter User Manual 