Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə23/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   19   20   21   22   23   24   25   26   ...   138
CSA C22.2 No. 0.15,
Adhesive Labels,
and UL 969,
Marking and Labeling Systems
ASTM D 471,
Standard Test Method for Rubber Property-Effect of Liquids
3 Definitions
For the purpose of this International Standard, the following definitions apply.
3.1.1 Where the terms voltage and current are used, they imply the r.m.s. values, unless otherwise
specified.
3.1.2 Where in this standard the expressions

with the aid of a tool

,

without the aid of a tool

, and

requires the use of a tool

, the word

tool

means a hand tool, for example screwdriver, which may be
used to operate a screw or other fixing means.
3.2.1 rated voltage : voltage assigned to the tool by the manufacturer. For three-phase supply, it is the
voltage between phases
3.2.2 rated voltage range : voltage range assigned to the tools by the manufacturer, expressed by its
lower and upper limits
3.2.3 working voltage : maximum voltage, without the effect of transient voltages, to which the part
under consideration is subjected when the tool is supplied at its rated voltage and operating under
normal load
3.2.4 rated input : input in watts assigned to the tool by the manufacturer
3.2.5 rated input range : input range in watts assigned to the tool by the manufacturer, expressed by its
lower and upper limits
3.2.6 rated current : current assigned to the tool by the manufacturer. If no current is assigned to the
tool, the rated current for the purpose of this standard is the current measured when the tool is under
normal load at rated voltage
3.2.7 rated frequency : frequency assigned to the tool by the manufacturer
3.2.8 rated frequency range : frequency range assigned to the tool by the manufacturer, expressed by
its lower and upper limits
3.2.9 normal load : load to be applied to a tool at rated voltage or at the upper limit of the rated voltage
range, to obtain rated input or rated current, any marking of short-time or intermittent operation being
observed and, unless otherwise specified, heating elements, if any, being operated as in normal use
3.2.9.1 no load input / current : highest input or current obtained when a tool is operated at rated
voltage and frequency with no external load (work) applied to the accessories packaged with the tool by
the manufacturer and adjusted according to manufacturer’s instructions, ready for use
3.2.10 rated no-load speed : no-load speed at rated voltage or at the upper limit of the rated voltage
range assigned to the tool by the manufacturer