Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


DV.1 D2 Addition: Add the following clause



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə64/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   60   61   62   63   64   65   66   67   ...   138
20.4DV.1 D2
Addition: Add the following clause:
At the discretion of the manufacturer, a separate sample shall be subjected to a single
impact on each handle and each recommended grasping surface. The impacts shall be
made from a height of 1 m onto a concrete surface followed by a 1,250 volt ac potential
between the grasping surfaces in contact with foil and the output shaft of the tool.
21 Construction
21.1 Tools which can be adjusted to suit different voltages, or to different speeds, shall be so constructed
that accidental changing of the setting is unlikely to occur, if such a change might result in a hazard.
Compliance is checked by inspection and by manual test.
21.2 Tools shall be so constructed that accidental changing of the setting of control devices is unlikely to
occur.
Compliance is checked by manual test.
21.3 It shall not be possible to remove parts which ensure the required degree of protection against
moisture without the aid of a tool.
Compliance is checked by manual test.
21.4 If handles, knobs and the like are used to indicate the position of switches or similar components, it
shall not be possible to fix them in a wrong position if this might result in a hazard.
Compliance is checked by inspection and by manual test.
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
58
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


21.5 Replacement of a flexible cable or cord requiring the moving of a switch which acts also as a
terminal for external conductors shall be possible without subjecting internal wiring to undue stress; after
repositioning the switch, and before reassembling the tool, it shall be possible to verify whether the
internal wiring is correctly positioned.
Compliance is checked by inspection and by manual test.
21.6 Wood, cotton, silk, ordinary paper and similar fibrous or hygroscopic material shall not be used as
insulation, unless impregnated.
Insulating material is considered to be impregnated if the interstices between the fibres of the material are
substantially filled with a suitable insulant.
Compliance is checked by inspection.
21.7 Asbestos shall not be used in the construction of tools.
Compliance is checked by inspection.
21.8 Driving belts shall not be relied upon to provide the required level of insulation.
This requirement does not apply if the tool incorporates a special design of belt which prevents
inappropriate replacement.
Compliance is checked by inspection.
21.9 Insulating barriers of class II tools, and parts of class II tools which serve as supplementary
insulation or reinforced insulation, and which might be omitted during reassembly after servicing, shall
either:
– be fixed in such a way that they cannot be removed without being seriously damaged; or