International refereed journal of design and architecture print issn



Yüklə 38,03 Mb.
Pdf görüntüsü
səhifə89/147
tarix17.11.2018
ölçüsü38,03 Mb.
#80180
1   ...   85   86   87   88   89   90   91   92   ...   147

MTD
www.mtddergisi.com
ULUSLARARASI HAKEMLİ TASARIM VE MİMARLIK DERGİSİ
Ocak  /  Şubat / Mart  / Nisan  2017 Sayı: 10 Kış - İlkbahar 
INTERNATIONALREFEREEDJOURNAL OF DESIGNANDARCHITECTURE
January / February / March / April 2017 Issue: 10 Winter – Spring
ID:121 K:205
ISSN Print: 2148-8142 Online: 2148-4880
 (ISO 18001-OH-0090-13001706 / ISO 14001-EM-0090-13001706 / ISO 9001-QM-0090-13001706 / ISO 10002-CM-0090-13001706)
(Marka Patent No / Trademark)
(2015/04018 – 2015/GE/17595)
194
ULUSLARARASI HAKEMLİ
TASARIM MİMARLIK DERGİSİ
INTERNATIONAL REFEREED
JOURNAL OF DESIGN AND ARCHITECTURE
PRINT ISSN: 2148-8142 - ONLINE ISSN: 2148-4880
programs related to climate, net area and vo-
lume  assumptions  and  construction  type,  as 
well as the defaults of each program, such as 
correlation coefficients and average values. 
Table 1. Convergence of the Results of EnAd for Heating, Cooling, DHW and Lighting
DesignBuilder
HAP
EnerCalc
Heating 
-18%
3%
5%
Cooling 
-22%
8%
1%
DHW
9%
-4%
-28%
Lighting
17%
10%
-8%
Usability of EnAd
Usability tests are also conducted to test the 
flexibility and ease of use of EnAd. The usa-
bility  of  the  program  is  tested  by  means  of 
a  prepared  protocol,  designed  to  check  the 
circumstances  under  which  users  have  tro-
uble  with  questions,  options,  values,  expla-
nations and activities. The results of the usa-
bility test reveal that the program is proven 
in  its  usability,  understandability,  efficiency 
and sufficiency, while also being informati-
ve for the user. They validate the usefulness 
of  the  explanations  and  feedback  provided 
by the program in improving the design. The 
results also show that using EnAd to assess 
the energy performance of a building is not 
a time consuming process, and can be done 
without the need for complex models. As a 
part of the usability test, Figure 14 presents 
time spent for each step of data input (steps 
1-4)  and  improvement  of  the  design  (steps 
5-10) in EnAd.


MTD
www.mtddergisi.com
ULUSLARARASI HAKEMLİ TASARIM VE MİMARLIK DERGİSİ
Ocak  /  Şubat / Mart  / Nisan  2017 Sayı: 10 Kış - İlkbahar 
INTERNATIONALREFEREEDJOURNAL OF DESIGNANDARCHITECTURE
January / February / March / April 2017 Issue: 10 Winter – Spring
ID:121 K:205
ISSN Print: 2148-8142 Online: 2148-4880
 (ISO 18001-OH-0090-13001706 / ISO 14001-EM-0090-13001706 / ISO 9001-QM-0090-13001706 / ISO 10002-CM-0090-13001706)
(Marka Patent No / Trademark)
(2015/04018 – 2015/GE/17595)
195
ULUSLARARASI HAKEMLİ
TASARIM MİMARLIK DERGİSİ
INTERNATIONAL REFEREED
JOURNAL OF DESIGN AND ARCHITECTURE
PRINT ISSN: 2148-8142 - ONLINE ISSN: 2148-4880
0
5
10
15
20
25
30
35
step1 step2 step3 step4 step5 step6 step7 step8 step9 step10
Du
ra
tio
n
Participant 1
Participant 2
Participant 3
Participant 4
Participant 5
Participant 6
Participant 7
Participant 8
Participant 9
Participant 10
Figure 14. Time Spent for Each Step of the Design in EnAd
CASE STUDY: EVALUATION of a LOW-
RISE BUILDING
Description of the Case Study
In this section, the use and major features of 
EnAd  has  been  exemplified  on  a  single-fa-
mily house, which is located in the western 
part  of Ankara.  The  house  selected  for  the 
case study is a terrace house, inhabited since 
1994. The terraces on the site feature between 
three and five houses; and the house selected 
for the study is the center dwelling in a terra-
ce of three houses, oriented in an east-west 
direction.  The  total  floor  area  of  the  house 
is 115 m
2
, of which 60m
2
 is the ground floor 
while the upper floor is 55m
2
. The ground flo-
or contains a living room, kitchen and toilet, 
and upstairs there are three bedrooms and a 
bathroom. The house features one meter wide 
cantilever floors on the first floor, and there 
are  no  balconies.  The  house  is  constructed 
using a sandwich wall system and has an un-
conditioned pitched roof. The ground floor is 
in contact with the earth, having no basement. 
It has low insulated walls with a U-value of 
0.80 W/m
2
K, and a moderately insulated gro-
und floor (0.60), ceiling (0.35) and cantilever 
floors (0.40). The windows are the standard 
type  for  Turkey  having  a  U-value  of  2.20 
while a very low window-wall ratio (WWR) 
is used, which is about 8%. Architectural dra-
wings of the building are provided in Figure 
15.


MTD
www.mtddergisi.com
ULUSLARARASI HAKEMLİ TASARIM VE MİMARLIK DERGİSİ
Ocak  /  Şubat / Mart  / Nisan  2017 Sayı: 10 Kış - İlkbahar 
INTERNATIONALREFEREEDJOURNAL OF DESIGNANDARCHITECTURE
January / February / March / April 2017 Issue: 10 Winter – Spring
ID:121 K:205
ISSN Print: 2148-8142 Online: 2148-4880
 (ISO 18001-OH-0090-13001706 / ISO 14001-EM-0090-13001706 / ISO 9001-QM-0090-13001706 / ISO 10002-CM-0090-13001706)
(Marka Patent No / Trademark)
(2015/04018 – 2015/GE/17595)
196
ULUSLARARASI HAKEMLİ
TASARIM MİMARLIK DERGİSİ
INTERNATIONAL REFEREED
JOURNAL OF DESIGN AND ARCHITECTURE
PRINT ISSN: 2148-8142 - ONLINE ISSN: 2148-4880
Figure 15. Ground Floor Plan (top) and Upper Floor Plan (below) 
Evaluation Results
The owner of the house provided architectural 
drawings, as well as data on natural gas and 
electricity consumption for the last four years 
in the form of bills. The house is heated by 
a  non-condensing  combustion  boiler  witho-
ut a programmer or thermostatic valves that 
also provides DHW. The property is naturally 
ventilated and has no air-conditioner for mec-
hanical cooling. Based on the data provided 
by the owner and the architectural project, the 
house is evaluated by EnAd and other three 
programs. Although the building is not coo-
led mechanically, the energy requirement for 
space  cooling  is  evaluated  for  comparison 
among the results of the programs. The eva-
luation results are presented in Table 2.


Yüklə 38,03 Mb.

Dostları ilə paylaş:
1   ...   85   86   87   88   89   90   91   92   ...   147




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©genderi.org 2024
rəhbərliyinə müraciət

    Ana səhifə