ISO-IEC 17025-2017

8.7  Corrective actions (Option A)

8.7.1 

When a nonconformity occurs, the laboratory shall:

a)  react to the nonconformity and, as applicable:

—  take action to control and correct it;

—  address the consequences;

b)  evaluate the need for action to eliminate the cause(s) of the nonconformity, in order that it does not 

recur or occur elsewhere, by:

—  reviewing and analysing the nonconformity;

—  determining the causes of the nonconformity;

—  determining if similar nonconformities exist, or could potentially occur;

c)  implement any action needed;

d)  review the effectiveness of any corrective action taken;

e)  update risks and opportunities determined during planning, if necessary;

f)  make changes to the management system, if necessary.



8.7.2 

Corrective actions shall be appropriate to the effects of the nonconformities encountered.



8.7.3 

The laboratory shall retain records as evidence of:

a)  the nature of the nonconformities, cause(s) and any subsequent actions taken;

b)  the results of any corrective action.