Microsoft Word Ksi\271\277ka abstrakt\363w doc



Yüklə 20,03 Mb.
Pdf görüntüsü
səhifə135/173
tarix17.11.2018
ölçüsü20,03 Mb.
#80416
1   ...   131   132   133   134   135   136   137   138   ...   173

 
 
 
 
 
 
 
XIV
h
 International Conference on Molecular Spectroscopy, Białka Tatrzańska 2017
 
282
T5: P–2 
Fourier-Transform spectroscopy and deperturbation analysis of the 
Ångström (B
1
Ʃ
+
 – A
1
Π) system in 
12
C
18

 
Rafał Hakalla
1
, Wojciech Szajna
1
, Mirosław Zachwieja
1
, Izabela Piotrowska
1

Małgorzata Ostrowska-Kopeć
1
, Przemysław Kolek
1
, and Ryszard Kępa
1
 
 

Materials Spectroscopy Laboratory, Department of Experimental Physics, Faculty of Mathematics  
and Natural Science, University of Rzeszów, ul. Prof. S. Pigonia 1, 35-959 Rzeszów, Poland, 
e-mail: hakalla@ur.edu.pl 
 
 
The  A
1
Π  (v  =  0)  level  of 
12
C
18
O has  been  reinvestigated  using  Fourier–transform  spectroscopy 
(1.71 m Bruker IFS 125 – HR spectrometer at the University of Rzeszów) probing visible wavelength 
emission  spectra  B
1
Ʃ
+
  –  A
1
Π  (0,  0)  band  under  0.018  cm
–1
  high–resolution.  The  discharge  was 
conducted in the air–cooled, carbon hollow–cathode (HC) lamp. The temperature of dc–plasma at the 
center of the cathode was 900 K. The estimated absolute calibration uncertainty (1σ) was 0.003 cm
–1

The fitting uncertainty of the line frequency measurements is estimated to be 0.003 cm-1 for single 
medium-strength lines and 0.01–0.02 cm
–1
 for weak and/or blended ones. 
 
An effective–Hamiltonian deperturbation analysis of A
1
Π (v = 0) level was performed up to J = 
40 and quantitatively addressing interactions by the e
3
Ʃ

 (v = 1), d
3
Δ
i
 (v = 4), a′
3
Ʃ
+
 (v = 9), D
1
Δ (v = 
0),  and  I
1
Ʃ

  (v  =  0,  1)  rovibrational  levels.  The  present  investigation  is  one  of  a  series  analyzing 
perturbations  in  low–v  levels  of  the  A
1
Π  state  in  detail  for  various  isotopologues  of  the  carbon 
monoxide molecule. These studies have provided a highly accurate picture of levels and perturbations 
for levels of A
1
Π in the 
12
C
16
O main isotopologue [1], 
13
C
16
O [2], 
12
C
17
O [3], 
13
C
17
O [4], and 
12
C
18

[this work].  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig. 1. High-resolution B
1
Ʃ
+
 – A
1
Π
 (0, 0) emission band in 
12
C
18
O recorded by 1.71m FT spectrometer. 
 
Keywords: high-resolution FT spectroscopy; deperturbation analysis, Ångström system; 
12
C
18
O isotopologue.  
 
References  
[1]  M.L. Niu, E.J. Salumbides, A.N. Heays, N. de Oliveira, R.W. Field, W. Ubachs, Mol. Phys. 114 (2016) 627. 
[2]  M.L. Niu, R.Hakalla, T.M. Trivikram, A.N. Heays, N. de Oliveira, E.J. Salumbides, W. Ubachs, Mol. Phys. 
114 (2016) 2857. 
[3]  R. Hakalla, M.L. Niu, R.W. Field, E.J. Salumbides, A.N. Heays, G. Stark, J.R. Lyons, M. Eidelsberg, J.L. 
Lemaire, S.R. Federman, et al., Roy. Soc. Chem. Adv. 6 (2016) 31588. 
[4]  R. Hakalla, M. Niu,  R.  Field, A.  Heays, E. Salumbides, G.  Stark, J.  Lyons, M.  Eidelsberg, J.  Lemaire, S. 
Federman, et al., J. Quant. Spectr. Rad. Transfer 189 (2017) 312. 


 
 
 
 
 
 
 
XIV
h
 International Conference on Molecular Spectroscopy, Białka Tatrzańska 2017
 
 
283
T5: P–3 
First FT spectroscopy of the comet-tail (A
2
Π
i
 – X
2
Ʃ
+
) system bands 
in 
12
C
17
O
+
 
 
Izabela Piotrowska
1
, Małgorzata Ostrowska-Kopeć
1
, Rafał Hakalla
1

Wojciech Szajna
1
, Mirosław Zachwieja
1
, Przemysław Kolek
1
, and Ryszard Kępa
1
 
 

Materials Spectroscopy Laboratory, Department of Experimental Physics, Faculty of Mathematics  
and Natural Science, University of Rzeszów, ul. Prof. S. Pigonia 1, 35-959 Rzeszów, Poland, 
e-mail: ipiotrowska@ur.edu.pl 
 
 
In  the  emission  spectrum  of 
12
C
17
O
+
  molecule  new  observations  and  analyses  were 
performed. Two bands (0–2 and 1–1) of the Comet–Tail (A
2
Π
i
 – X
2
Ʃ
+
) system in the 19850 to 
15250 cm
–1
 region were recorded with the Fourier transform spectrometer (BRUKER IFS 125-
HR).  
 
The  absolute  accuracy  of  wavenumbers  was  about  0.003  cm
–1
.  The  measurement  cycle 
included  128  scans  within  1.5  h.  As  a  source  of  the  studied  spectrum  an  air-cooled,  carbon 
hollow-cathode (HC) lamp operated at 780 V, 54 mA dc was used. The lamp was filled with a 
static  mixture  of 
17
O
2
  (70  %)  and 
16
O
2
  (30  %)  at  a  pressure  of  3  mbar.  During  the  discharge 
process, the O
2
 molecules react with the 12C atoms ejected from the carbon filler placed inside 
the cathode, thus forming 
12
C
17
O and 
12
C
17
O
+
 molecules in the gas phase, in amounts sufficient 
to finally achieve a signal-to-noise ratio (SNR) of 100:1.  
 
Spectra were analyzed using a commercial software OPUS which finds peaks and calculates 
various  spectral  parameters  (wavenumbers,  FWHM,  etc).  As  a  result  of  a  detailed  spectral 
analysis the individual molecular constants of both A
2
Π
i
 and X
2
Ʃ
+
 states were obtained. For the 
upper  A
2
Π
i
  state  all  these  constants  were  delivered  for  the  first  time.  The  parameters  for  the 
lower X
2
Ʃ
+
 state were also calculated and compared with these determined previously [1–3]. 
 
Fig. 1. B
1
Ʃ
+
 – A
1
Π
 bands in 
12
C
17
O and A
2
Π
i
 – X
2
Ʃ
+
 bands in 
12
C
17
O
+

 
Keywords: FT spectroscopy; Comet-tail system; 12C17O+ molecule  
 
References  
[1]  W. Szajna, R. Kępa, Spectrochim. Acta A 65 (2006) 1014. 
[2]  W. Szajna, R. Kępa, R. Hakalla, M. Zachwieja, J. Mol. Spectrosc. 240 (2006) 75. 
[3]  W. Szajna, R. Kępa, R. Hakalla, M. Zachwieja, Spectrosc. Lett. 40 (2007) 667. 


Yüklə 20,03 Mb.

Dostları ilə paylaş:
1   ...   131   132   133   134   135   136   137   138   ...   173




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©genderi.org 2024
rəhbərliyinə müraciət

    Ana səhifə