RETICLE INSPECTION ISSUES
Worst case (currently typical), the mask cannot be inspected at all
Rule-Based Tiling
Done
with Boolean operations
Only density of the template is variable
Not
adequate for arbitrary design
Model-Based Tiling
RETICLE INSPECTION ISSUES
Defectivity is the most serious problem
affecting reticle delivery
More acute with the introduction of OPC
OPC features do not resolve as
drawn in the design on reticle
When inspected, OPC results in vast numbers
of false defect detections
Worst case (currently typical), the mask cannot be inspected at all
Standard practice:
De-sense reticle inspection tool so partially resolved
OPC shapes do not cause errors
De-sensing for OPC also de-senses the tool to legitimate defects