Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


Parts of rubber are aged at a temperature of (100



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə67/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   63   64   65   66   67   68   69   70   ...   138

Parts of rubber are aged at a temperature of (100
±
2) °C for 70 h. After the test, the samples are
examined, and shall show no crack visible to the naked eye.
NOTE In case of doubt with regard to materials other than rubber, special tests may be made.
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
61
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


21.14 Tools shall be so constructed that internal wiring, windings, commutators, slip rings and the like,
and insulation in general, are not exposed to oil, grease or similar substances.
If the construction necessitates that insulation be exposed to oil or grease or similar substance, as in
gears and the like, the oil or grease or substance shall have adequate insulating properties so that
compliance with the standard is not impaired, and shall have no effect on insulation.
Compliance is checked by inspection and by the tests of this standard.
21.15 It shall not be possible to gain access to brushes without the aid of a tool.
Screw-type brush-caps shall be so designed that, when tightening, two surfaces are clamped together.
Brush-holders, which retain the brushes in position by means of a locking device, shall be so designed
that the locking does not depend upon the brush-spring tension, if the loosening of the locking device
might make accessible metal parts live.
Screw-type brush-caps, which are accessible from the outside of the tool, shall be of insulating material,
or be covered with insulating material of adequate mechanical and electrical strength; they shall not
project beyond the surrounding surface of the tool.
Compliance is checked by inspection and by manual test, the properties of the insulating material being
verified:
– by the tests of 20.2 and 20.4 for screw-type brush-caps which are accessible from the
outside of the tool;
– by the tests specified for supplementary insulation for class I tools and class III tools;
– by the tests specified for reinforced insulation for class II tools.
21.16 Tools with water supply shall be either of class III, or designed for use in conjunction with an
isolating transformer having a rated output voltage not exceeding 115 V.