Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


Following this test, the tool shall meet the test of 13.1 after being allowed to dry for 24



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə69/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   65   66   67   68   69   70   71   72   ...   138
Following this test, the tool shall meet the test of 13.1 after being allowed to dry for 24
hours at room temperature.
21.17 Switches and reset buttons on non-self-resetting controls shall be so located that accidental
operation is unlikely to occur.
Compliance is checked by inspection, and by the following test:
The tool is connected to the power supply, placed in any possible position and dragged across a
horizontal surface.
Inadvertent operation of the switch shall not then occur.
21.18 Tools, other than those provided with a flexible shaft, shall be fitted with a mains switch which can
be switched off by the user without releasing his grasp on the tool. When a switch has a locking
arrangement to lock it in the ON position, the requirement in 21.18 is considered as being met provided
the switch unlocks automatically when the trigger or actuating member is actuated.
Compliance is checked by inspection and by manual test.
21.18.1 Where there is a risk associated with continued operation, the switch shall not have any locking
device to lock it on the ON position and it shall not remain in the ON position when the trigger is released.
This shall be stated in the relevant part 2.
21.18.2 Where there is a risk associated with inadvertent starting, the switch shall have a locking device
to lock it on the OFF position. This shall be stated in the relevant part 2.
21.19 Tools shall be so designed that the protection against electric shock is not affected when screws
intended for replacement from the outside during routine servicing are replaced by screws having a
greater length.
Compliance is checked by inserting longer screws, without appreciable force, after which creepage
distances and clearances between live parts and accessible metal parts shall not have been reduced
below the values specified in 28.1.
21.20 If the tool is marked with the first numeral of the IP system, the relevant requirements of IEC 60529
shall be fulfilled.
Compliance is checked by making the relevant tests.