MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
90
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


28.2 The distance through insulation, for working voltages up to and including 250 V, between metal parts
shall not be less than 1,0 mm if they are separated by supplementary insulation, and not be less than 2,0
mm if they are separated by reinforced insulation.
This requirement does not apply if the insulation is applied in thin sheet form, other than mica or similar
scaly material, and consists:
– for supplementary insulation, of at least two layers, provided that any one of the layers
withstands the electric strength test prescribed for supplementary insulation;
– for reinforced insulation, of at least three layers, provided that, when any two of the layers
are placed in contact, they withstand the electric strength test prescribed for reinforced
insulation.
The test voltage is applied between the outer surfaces of the layer, or of the two layers, as applicable.
Moreover, this requirement does not apply if the supplementary insulation or the reinforced insulation is
inaccessible, and meets one of the following conditions:
– the maximum temperature rise determined during the tests of clause 12 does not exceed the
permissible value specified in 12.5;
– the insulation, after having been conditioned for seven days (168 h) in a oven maintained at
a temperature equal to 50 K greater than the maximum temperature rise determined during the
tests of clause 12, withstands an electric strength test as specified in clause 15, this test being
made on the insulation both at the temperature occurring in the oven, and at approximately
room temperature.
This requirement does not imply that the prescribed distance must be through solid insulation only; it may
consist of thickness of solid insulation plus one or more air layers.
Compliance is checked by inspection and by measurement.
For tools having parts with double insulation, where there is no metal between basic insulation and
supplementary insulation, the measurements are made as though a metal foil were present between the
two insulations.
For optocouplers, the conditioning procedure is carried out at a temperature of 50 K in excess of the
maximum temperature rise measured on the optocoupler during the tests of clause 12 and 18, the
optocoupler being operated under the most onerous conditions which occur during these tests.

Yüklə 4,83 Kb.