23
TO SET - HOUR FORMAT
Factory set for 12 Hour (12: AM to 11: PM), the Hour Format
can also be set for 24 Hour (0: to 23: hours).
• After having set and accepted Units, the Set Hour Format
screen appears with the Set Point flashing (Fig. 20).
- - or - -
• While the Surface Sequence is scrolling, depress the button
for 8 seconds to bypass Set FO2, Wet Activation, and Units,
then release the button.
• Press/release the button (less than 2 seconds) to toggle
between 12 and 24.
• Depress the button for 2 seconds to accept the Set Point and
advance to Set Time.
Fig. 20 - SET HOUR
FORMAT
24
TO SET - TIME
Set for factory local time, the Time can be set to values between
1:00 and 12:59 (AM/PM) or 0:00 and 23:59.
• After having set and accepted Hour Format, the Set Time
screen appears with the Hour Set Point flashing (Fig. 21).
- - or - -
• While the Surface Sequence is scrolling, press the button for
10 seconds to bypass Set FO2, Wet Activation, Units, and
Hour Format, then release the button.
• Press/release the button repeatedly (less than 2 seconds
each time) to advance the Hour Set Point in increments of 1
Hour per press of the button.
• Depress the button for 2 seconds to accept the Hour Set
Point, the Minutes Set Point flashes.
• Press/release the button repeatedly (less than 2 seconds
each time) to advance the Minute Set Point in increments of 1
Minute per press of the button.
• Depress the button for 2 seconds to accept the Minute Set
Point and advance to Set PO2 Alarm.
Fig. 21 - SET TIME
25
TO SET - PO2 ALARM
Factory set for 1.60 (ATA), the PO2 Alarm can be set to values
between 1.20 and 1.60 (ATA) in increments of .10 (ATA).
• After having set and accepted the Time, the Set PO2 Alarm
screen appears with the Set Point flashing (Fig. 22).
- - or - -
• While the Surface Sequence is scrolling, press the button for
14 seconds to bypass Set FO2, Wet Activation, Units, Hour
Format, and Time, then release the button.
• Press/release the button repeatedly (less than 2 seconds
each time) to advance the PO2 Alarm setting in increments
of .10 (ATA) per press of the button.
• Depress the button for 2 seconds to accept the PO2 Alarm
Set Point and advance to Set FO2 Default.
Fig. 22 - SET PO2 ALARM
26
TO SET - FO2 50% DEFAULT
Factory set ON, the FO2 50% Default feature can be set to
OFF. The effects of this feature being ON or OFF are described
on page 16.
• After having set and accepted the PO2 Alarm Set Point, the
Set FO2 50% Default screen appears with the Set Point
flashing (Fig. 23).
- - or - -
• While the Surface Sequence is scrolling, depress the button
for 16 seconds, then release it when the Set FO2 50 screen
appears with the Set Point flashing.
• Press/release the button (less than 2 seconds) to toggle
between ON and OFF.
• Depress the button for 2 seconds to accept the Set Point and
advance to Set No Deco Deep Stop.
Fig. 23 - SET FO2 DEFAULT
27
TO SET - NO DECO DEEP STOP (DS)
Factory set OFF, the No Deco Deep Stop feature can be set to
ON. The effects of this feature being ON or OFF are described
on page 34.
• After having set and accepted the FO2 50% Default Set
Point, the Set DS screen appears with the Set Point flashing
(Fig. 24).
- - or - -
• While the Surface Sequence is scrolling, depress the button
for 18 seconds, then release it when the Set DS screen
appears with the Set Point flashing.
• Press/release the button (less than 2 seconds) to toggle
between ON and OFF.
• Depress the button for 2 seconds to accept the Set Point and
revert to the Surface Sequence.
Fig. 24 - SET DEEP STOP
28
• It should not be considered that the capabilities built into the Element provide
an implied approval or consent from TUSA for individuals to exceed the defined
limits for recreational diving, as agreed on by all internationally recognized
training agencies.
• The oxygen features of the Element are intended for use by recreational divers
trained for nitrox diving by an instructor certified by a recognized training
agency to teach diving with nitrox.
• Conducting repetitive dives using enriched nitrogen-oxygen mixtures can lead
to oxygen buildup, reducing oxygen tolerance while increasing the risk of
pulmonary oxygen toxicity.
• The Element provides information based upon a personal dive profile, and
therefore must not be shared between divers. It is impossible for two divers to
stay precisely together underwater, and your computer's dive profile tracking
of previous dives will be pertinent to you only. Nitrogen and oxygen loading of
a second user may be significantly different and swapping dive computers
could lead to inaccurate and dangerous predictions of decompression and
oxygen accumulation status.
WARNINGS AND SAFETY RECOMMENDATIONS
Dostları ilə paylaş: |