12 Heating
12.1 Tools shall not attain excessive temperatures under normal load.
Compliance is checked by determining the temperature rise of the various parts under the conditions
specified in 12.2 to 12.5 immediately followed by the test of clause 13 with the tool in the

on

position
and under the following conditions:
For single-phase tools and for three-phase tools to be tested as single-phase tools:
S1 of Figure 3 in the

on

position.
For three-phase tools not suitable for single-phase supply:
a, b and c in Figure 4 in the

on

position.
For heating elements, the measurements are repeated with each of the switches a, b and c open in turn,
the other two switches being closed.
12.2 The tool is operated in still air under normal load. While the torque is maintained, the voltage is then
adjusted to 0,94 times the rated voltage or 1,06 times the rated voltage, or the mean of the rated voltage
range, whichever is the most unfavourable.
Heating elements, if any, are operated under the conditions specified in clause 11 of IEC 60335-1, when
the tool is operated at a voltage equal to 1,06 times rated voltage.
12.3 Temperature rises, other than those of windings, are determined by means of fine-wire
thermocouples so chosen and positioned that they have the minimum effect on the temperature of the part
under test.
The temperature rise of electrical insulation, other than that of windings, is determined on the surface of
insulation, at places where failure could cause a short circuit, contact between live parts and accessible
metal parts, bridging of insulation, or reduction of creepage distances or clearances below the values
specified in 28.1.
Temperature rises of windings are determined by the resistance method, unless the windings are
non-uniform, or the method involves severe complications to make the necessary connections for the
resistance measurement. In that case, the measurement is made by thermocouples.
Such temperature rises are determined by means of fine-wire thermocouples so chosen and positioned
that they have the minimum effect on the temperature of the part under test.
In determining the temperature rises of handles, knobs, grips and the like, consideration is given to all
parts which are gripped in normal use, and, if of insulating material, to those parts in contact with hot
metal.