Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


NOTE 1 If it is necessary to dismantle the tool to position thermocouples, the power input is measured again to



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə47/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   43   44   45   46   47   48   49   50   ...   138
NOTE 1 If it is necessary to dismantle the tool to position thermocouples, the power input is measured again to
check that the tool has been correctly reassembled.
NOTE 2 The point of separation of the cores of a multicore cord is an example of a place where thermocouples
are positioned.
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
41
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


12.4 The tool is operated:
– for the rated operating time for tools for short-time operation;
– on consecutive cycles of operation, until steady thermal conditions are established, for tools
for intermittent operation, the

on

and

off

periods being the rated

on

and

off

periods;
– until steady thermal conditions are established for all other tools for continuous operation.
12.5 During the test, protective devices shall not operate. The temperature rises shall not exceed the
values shown in Table 1, except as allowed by 12.6.
Sealing compound, if any, shall not flow out.
Table 1 – Maximum normal temperature rises
Parts
Temperature rise K
Windings
1)
, if the winding insulation according to IEC 60085 is:
– class A
75
(65)
– class E
90
(80)
– class B
95
(85)
– class F
115
– class H
140
– class 200
160
– class 220
180
– class 250
210
Pins of appliance inlets:
– for hot conditions
95
– for cold conditions
40
Ambient of switches, temperature limiters
2)
:
– without T-marking
30
– with T-marking
T-25
Rubber or polyvinyl chloride insulation of internal and external wiring,
including supply cords:
– without temperature rating
3)
50
– with temperature rating (T)
T-25
Cord sheath used as supplementary insulation
35
Rubber, other than synthetic, used for gaskets or other parts, the
deterioration of which could affect safety:
– when used as supplementary insulation or as reinforced insulation
40
– in other cases
50
Lampholders E14 and B15:
– metal or ceramic type
130
– insulated type, other than ceramic
90
– with T-marking
T-25
Material used as insulation other than that specified for wires and
windings
4)
– impregnated or varnished textile, paper or press board