- for class III tools 0,5 mA.
If the tool incorporates one or more capacitors, and is provided with a single-pole switch, the
measurements are repeated with the switch in the
″
off
″
position.
For tools with heating elements, the total leakage current may be within the limits specified for heating
elements, as specified in clause 16 of IEC 60335-1, or for motor-operated tools, whichever is the greater,
but the two limits are not added.
13.2DV D2
Modification: Replace the class I tools item with the following:
- for class I tools 0,5 mA;
14 Moisture resistance
14.1 The enclosure of the tool shall provide the degree of protection against moisture in accordance with
the classification of the tool.
Compliance is checked by the appropriate treatment specified in 14.1.2, with the tool conditions as in
14.1.1.
14.1.1 The tool is not connected to the supply.
Tools are turned continuously through the most unfavourable positions during the test.
Tools with type X attachment are fitted with the lightest permissible type of flexible cord of the smallest
cross-sectional area specified in 25.2; other tools are tested as delivered.
Electrical components, covers and other parts which can be removed without the aid of a tool are removed
and subjected, if necessary, to the relevant treatment with the main part.
14.1.2 Tools other than IPX0 are subjected to tests of IEC 60529 as follows:
– IPX1 tools are subjected to the test described in 14.2.1;
– IPX2 tools are subjected to the test described in 14.2.2;
– IPX3 tools are subjected to the test described in 14.2.3;
– IPX4 tools are subjected to the test described in 14.2.4;
– IPX5 tools are subjected to the test described in 14.2.5;
– IPX6 tools are subjected to the test described in 14.2.6;
Dostları ilə paylaş: