16 Overload protection of transformers and associated circuits
16.1 Tools incorporating circuits supplied from a transformer shall be so constructed that, in the event of
short circuits which are likely to occur in normal use, excessive temperatures do not occur in the
transformer, or in the circuits associated to the transformer.
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
50
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


NOTE Protection of transformer windings may be, for example, obtained by the inherent impedance of the
winding, or by means of fuses, automatic switches, thermal cut-outs or similar devices incorporated in the
transformer, or similar devices located inside the tool only accessible with the aid of a tool.
Examples of short-circuits which are likely to occur in normal use are the short-circuiting of bare or
inadequately insulated conductors of safety extra-low voltage circuits which are accessible, and the
internal short-circuiting of lamp filaments.
A failure of insulation complying with the requirements specified for basic insulation of class I or class II
construction is not, for the purpose of this requirement, considered as likely to occur in normal use.
Compliance is checked by applying the most unfavourable short circuit or overload which is likely to occur
in normal use, the tool being operated at a voltage equal to 1,06 times, or 0,94 times, rated voltage,
whichever is the more unfavourable.
The temperature rise of the insulation of the conductors of safety extra-low voltage circuits is determined,
and shall not exceed the relevant value specified in Table 1 by more than 15 K.
The winding temperature of transformers shall not exceed the value specified for windings in 18.9, except
for transformers which comply with IEC 61558-1.
17 Endurance
17.1 Tools shall be so constructed that, in extended normal use, there will be no electrical or mechanical
failure that might impair compliance with this standard. The insulation shall not be damaged and contacts
and connections shall not work loose as a result of heating, vibrations, etc.
Moreover, overload protection devices shall not operate under normal running conditions.
Compliance is checked by the test of 17.2 and, for tools provided with a centrifugal or other starting switch,
also by the test of 17.3.
Immediately after these tests, the tool shall withstand an electric strength test as specified in clause 15,
the test voltages being, however, reduced to 75 % of the specified values. Connections shall not have
worked loose, and there shall be no deterioration impairing safety in normal use.