17
WARNING: During Activation and Diagnostics, if any display or function
varies from the information presented here, return the Element to your
Authorized TUSA Dealer for inspection.
ACTIVATION and
SETUP
18
ACTIVATION
WARNING: If the unit is activated at elevations
higher than 14,000 feet (4,270 meters), it will per-
form a diagnostic check and immediately shutdown.
To Activate the Element, press and release the Button.
• Upon manual activation, the unit will enter Diagnostic
Mode (Fig. 13), displaying all segments of the LCD as 8's,
followed by dashes ( - - ), then a countdown from 9 to 0.
Diagnostic Mode checks the display and Battery voltage to
ensure that everything is within tolerance and functioning
properly.
• When the button is held depressed and the Diagnostic
countdown reaches 00, a Serial Number screen appears
displaying the unit’s Serial Number and firmware code
Revision Number as long as the button is held depressed
(Fig. 14). Upon releasing the button, the unit shuts Off.
• After manual activation, it will also check the ambient
barometric pressure, and calibrate its present depth as
zero. At elevations of 3,000 feet (915 meters) or higher, it
will recalibrate itself to measure depth at that higher Alti-
tude.
Fig. 13 - DIAGNOSTIC MODE
Fig. 14 - SERIAL NUMBER
19
Wet Contact Activation (only if set ON)
The Element will also automatically activate by Wet Contact.
This is accomplished by bridging the gap between contacts
located on the Button's stem and back of the case.
If no dive is made within 2 hours after initial activation, the unit
will automatically deactivate. If the wet contacts are still
bridged, the unit will reactivate and display the H2O graphic.
SURFACE SEQUENCE
While on the surface, the unit will automatically scroll through a
Sequence of displays including -
• Surface Mode
• Fly Mode
• DeSat Mode
• Plan Mode
As the Surface Sequence is scrolling, you can use the button to
access Log Mode and Set Mode.
SURFACE MODE
Surface Mode, identified by the Surface Time icon (Fig. 15a),
follows Diagnostic Mode after Activation. Information includes
Surface Time with flashing colon (and clock/wave icon, Tem-
perature (with icon and graphic C or F), Time of Day (with clock
icon), and Dive Number with # icon (0 if no dive made yet).
Fig. 15 - SURFACE MODE
a
20
SET MODE
After gaining access to Set Mode, settings can be made in
sequence one after the other, or you can access a specific item
that you want to set, bypassing others.
To access Set Mode while the Surface Sequence is scrolling,
press the button for 2 seconds.
• Upon entry into Set Mode, the Set FO2 screen will be
displayed with the Set Point flashing (Fig. 16).
• If the button is not pressed during a 2 minute period while in
the Set Mode, the unit will revert to Surface Mode and
resume the Surface Sequence scroll.
TO SET - FO2
Each time the unit is activated (if Off), FO2 will be automatically
set for a default value of AIR which can then be changed to
values between 21 and 50% in increments of 1%.
• While the Surface Sequence is scrolling, depress the button
for 2 seconds.
• Release the button when the FO2 screen appears with the
Set Point flashing.
• Press/release the button repeatedly to increase the FO2
value from 21 to 50% in increments of 1%, then display AIR
again.
Fig. 16 - SET MODE ENTRY
21
• For each FO2 value that appears, the Maximum Depth that
can be achieved for the PO2 Alarm Set Point will be dis-
played (Fig. 17a) with the graphic PO2. If FO2 is set for
AIR, no Depth value will be displayed.
• Depress the button for 2 seconds to accept the FO2 Set Point
displayed and advance to the Set Wet Activation screen.
TO SET - WET ACTIVATION
Factory set for ON, Wet Activation can also be set OFF (dis-
abled) to prevent inadvertent activation during travel or storage.
When set ON, the Element will automatically Activate and enter
Dive Mode upon immersion in water.
• After having set and accepted the FO2 setting, the Set Wet
Activation screen appears displaying the graphics ACt and
WET with the Set Point flashing (Fig. 18).
- - or - -
• While the Surface Sequence is scrolling, depress the button
for 4 seconds to bypass Set FO2 to access the screen, then
release the button.
Fig. 17 - FO2 set for 32%
(130 feet allowed)
a
Fig. 18 - SET WET
ACTIVATION
22
• Press/release the button (less than 2 seconds) to toggle
between ON and OFF.
• Depress the button for 2 seconds to accept the Set Point and
advance to Set Units Of Measure.
TO SET - UNITS OF MEASURE
Factory set for Imperial, Units of can also be set for Metric.
• After having set and accepted Wet Activation, the Set Units
screen appears with the Set Point flashing (Fig. 19).
- - or - -
• While the Surface Sequence is scrolling, depress the button
for 6 seconds to bypass Set FO2 and Set Wet Activation,
then release the button.
• Press/release the button (less than 2 seconds) to toggle
between Metric (M and C) and Imperial (FT and F) units.
• Depress the button for 2 seconds to accept the Units Set Point
and advance to Set Hour Format.
Fig. 19 - SET UNITS OF
MEASURE
Dostları ilə paylaş: |