Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


K.24 Supply connection and external flexible cords



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə124/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   120   121   122   123   124   125   126   127   ...   138
K.24 Supply connection and external flexible cords
This clause is not applicable, except as follows:
K.24.101 For battery tools with separable battery packs, the external flexible cable or cord shall have
anchorages such that the conductors are relieved from strain, including twisting, where they are
connected within the tool, and protected from abrasion.
Compliance is checked by inspection.
K.25 Terminals for external conductors
This clause is not applicable.
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
128
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


K.26 Provision for earthing
This clause is not applicable.
K.27 Screws and connections
K.27.1 This clause of the standard is applicable except as follows: Paragraph 6 and the accompanying
note, which refers to earthing conductors, is not applicable.
K.28 Creepage distances, clearances and distances through insulation
K.28.1 Creepage distances and clearances shall not be less than the values in millimetres shown in Table
K.2. The clearances specified do not apply to the air gap between the contacts of thermal controls,
overload protection devices, switches of micro-gap construction, and the like, or to the air gap between
the current-carrying members of such devices where the clearances vary with the movement of the
contacts. Creepages and clearances also do not apply to the construction of battery cells or the
interconnections between cells in a battery pack. The values specified in Table K.2 do not apply to
cross-over points of motor windings.
For parts having a hazardous voltage between them, the sum total of the measured distances between
each of these parts and their nearest accessible surface shall not be less than 1,5 mm clearance and 2,0
mm creepage.