Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


L.24 Supply connection and external flexible cords



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə135/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   130   131   132   133   134   135   136   137   138
L.24 Supply connection and external flexible cords
L.24.1 This subclause also applies to a flexible cord between a non-isolated power source and the tool.
L.24.3 This subclause also applies to a flexible cord between a non-isolated power source and the tool.
L.24.4 This subclause applies except a flexible cord provided between a non-isolated power source and
the tool shall not be provided with a plug that can be connected directly to the mains.
L.24.5 This subclause does not apply to a flexible cord provided between a non-isolated power source
and the tool.
L.24.21 This subclause applies except a flexible cord provided between a non-isolated power source and
the tool shall not be provided with an appliance inlet that can be connected directly to the mains.
L.24.101 For battery tools with separable battery packs, the external flexible cable or cord shall have
anchorages such that the conductors are relieved from strain, including twisting, where they are
connected within the tool, and protected from abrasion.
Compliance is checked by inspection.
L.25 Terminals for external conductors
This clause does not apply to interconnecting cords.
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
139
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


L.26 Provision for earthing
This clause only applies when the tool is in the configuration where it is directly connected to the mains
or a non-isolated source.
L.28 Creepage distances, clearances and distances through insulation
The clause of the standard is applicable except as follows:
L.28.1 Addition:
This subclause only applies when the tool is in the configuration where it is directly connected to the mains
or a non-isolated source. During the evaluation in this condition, battery packs are to be connected to the
tool. The tool is also evaluated with the battery pack removed if such removal can be accomplished
without the use of a tool.
L.28.101
Creepage distances and clearances shall not be less than values in millimetres shown in Table L.1. The
clearances specified do not apply to the air gap between the contacts of thermal controls, overload
protection devices, switches of micro-gap construction, and the like, or to the air gap between the
current-carrying members of such devices where the clearances vary with the movement of the contacts.
Creepages and clearances also do not apply to the construction of battery cells or the interconnections
between cells in a battery pack. The values specified in Table L.1 do not apply to cross-over points of
motor windings.
For parts having a hazardous voltage between them, the sum total of the measured distances between
each of these parts and their nearest accessible surface shall not be less than 1,5 mm clearance and 2,0
mm creepage.