Examples for the three positions are horizontal, vertically up and vertically down.
17.3 Tools provided with a centrifugal or other automatic starting switch are started 10 000 times under
normal load, and at a voltage equal to 0,9 times rated voltage, the operating cycle being that specified in
17.2.
18 Abnormal operation
18.1 Tools shall be so designed that the risk of fire and mechanical damage impairing safety or the
protection against electric shock as a result of abnormal operation is obviated as far as is practicable.
Fuses, thermal cut-outs, overcurrent protection devices or the like, incorporated into the tool, may be used
to provide the necessary protection.
Compliance is checked by the following tests of 18.2 to 18.9.
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
52
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


18.2 Tools incorporating heating elements are subjected to the tests of 18.3 and 18.4. Moreover, tools
provided with a control limiting the temperature during clause 12 tests unless specifically excluded by part
2, are subjected to the tests of 18.5, and where applicable, to the test of 18.6.
Only one abnormal condition is simulated each time. If more than one of the tests are applicable to the
same tool, these tests are made consecutively.
Unless otherwise specified, the tests are continued until a non-self-resetting thermal cut-out operates, or
until steady conditions are established. If, during the test, a heating element or an intentionally weak part
is permanently open-circuited, the relevant test is repeated on a second sample. This second test shall
be terminated in the same way, unless the test is otherwise satisfactorily completed.
An intentionally weak part is a part intended to fail under conditions of abnormal operation so as to prevent
the occurrence of a condition which could impair compliance with this standard. Such a part may be a
replaceable component, such as a resistor, a capacitor, or a thermal link, or a part of a component to be
replaced, such as an inaccessible and non-resettable thermal cut-out incorporated in a motor.
18.3 Tools with heating elements are tested under the conditions specified in clause 12, but with
restricted heat dissipation. The supply voltage, determined prior to the test, is that required to provide a
power input of 0,85 times the rated power input under normal operation, when steady conditions have
been established. This voltage is maintained throughout the test.
The tool is allowed to cool down to approximately room temperature before being subjected to the test of
18.4.
18.4 The test of 18.3 is repeated, but with a supply voltage, determined prior to the test, equal to that
required to provide a power input of 1,24 times rated power input under normal operation, when steady
conditions have been established. This voltage is maintained throughout the test.
18.5 The tool is tested under the conditions specified in clause 12, under normal operation, the supply
voltage being such that the power input is 1,15 times rated power input, but with any control which limits
the temperature during the test of clause 12 short-circuited.
If the tool is provided with more than one control, these are short-circuited in turn.
18.6 Unless an all-pole disconnection occurs during the test of 18.5 for class I tools with tubular sheathed
and embedded heating elements, but which are not intended to be permanently connected to fixed wiring,
the test of 18.5 is repeated, with the controls which limit the temperature during the test of clause 12 not
short-circuited, and one end of the element connected to earth. This test is repeated with the polarity of
the supply to the tool reversed and with the other end of the element connected to earth.
18.7 The following test is performed with cutting tools, such as sawblades, grinding wheels, etc.,
removed.
– Tools incorporating a commutator motor are operated at a voltage equal to 1,3 times rated
voltage, or the upper limit of the voltage range, for 1 min at no-load.
After the tests of 18.2 to 18.7, the safety of the tool shall not have been impaired, in particular windings
and connections shall not have worked loose. After the test, the tool need not be capable of further use.