33
CONTROL OF DISPLAYS
During dives, there is a Main (default) Display with Alternate
screens of information that can be accessed temporarily by
pressing the button.
NO DECOMPRESSION DIVE MODE
The Element will enter the No Decompression Dive Mode when
you descend to 5 FT (1.5 M) for 5 seconds.
No Deco Dive Main Display (Fig. 28)
Information includes Dive Time Remaining with Mode icon (Fig.
28a), Elapsed Dive Time (Fig. 28b), Current Depth (Fig. 28c),
and applicable bar graphs.
• Press/release the button 1 time (< 2 seconds) to view No
Deco Dive Alternate 1 Display.
• If set for Nitrox, press/release the button while viewing
Alternate 1 to view Alternate 2.
• The Alternate Displays will revert to the Main after 5 seconds
unless the button is pressed.
• Depress the button for 2 seconds to view a No Deco Deep
Stop Preview screen for 5 seconds.
No Deco Alternate 1 Display (Fig. 29)
Information includes Temperature, Time of Day, and Max Depth
with icons.
Fig. 28 - NO DECO MAIN
a
c
b
Fig. 29 - NO DECO ALT 1
34
No Deco Alternate 2 Display (Fig. 30)
The ALT 2 display will not appear when FO2 is set for AIR.
Information includes the graphic FO2, current value of PO2 with
graphic PO2, and the FO2 value set (21 to 50).
No Deco Dive DEEP STOP
On any No Deco dive in which Depth exceeds 80 FT (24 M), a
Deep Stop Preview screen (Fig. 31) can be accessed that will
display the graphic DS (meaning Deep Stop) and a recom-
mended Stop Depth of 1/2 the Max Depth and Stop Time of
02:00 (2 minutes) with DS and STOP bar icons. It will revert to
the Main after 5 seconds.
• To access the Preview screen, depress the button for 2
seconds while viewing the No Deco Main screen.
• The intent of this screen is to suggest that a stop should be
made to help reduce tissue loading prior to final ascent.
• The Preview screen will not be available for display once
you ascend above the calculated Stop Depth.
NOTE: The Deep Stop is not required and although
recommended, it does not have to be taken. There
will be no penalty if the Stop is ignored and ascent
(or other activity) is continued.
Fig. 30 - NO DECO ALT 2
Fig. 31 - NO DECO DEEP
STOP PREVIEW
35
Upon ascending to within10 FT (3 M) below the Stop Depth, the
Deep Stop Main screen (Fig. 32) will automatically appear
displaying the Stop Depth (1/2 Max Depth) with the 2 minute
Countdown Timer that counts down from 02:00 to 0:00
(min:sec). Also displayed will be Dive Time Remaining, current
Depth and applicable bar graphs.
Press and release the button (< 2 seconds) to access the ALT 1
screen that displays Elapsed Dive Time (Fig. 33), press it again
to view the ALT 2 screen displaying Temperature, Time, and
Max Depth (similar to figure 29), then if a Nitrox dive press it
again to view ALT 3 displaying FO2 and PO2 (similar to figure
30).
> If you descend 10 FT (3 M) below, or ascend 10 FT (3 M)
above, the calculated Stop Depth for 10 seconds during the
countdown, the No Deco Main will replace the DS Main
display and the DS feature will be disabled for the
remainder of that dive.
> In the event that you enter Deco, exceed 190 FT (57 M), or
a High O2 condition (=> 80%) occurs, the DS will be
disabled for the remainder of that dive.
> The DS is disabled during a High PO2 Alarm condition
(when => Set Point).
Fig. 32 - DEEP STOP MAIN
Fig. 33 - DEEP STOP ALT 1
36
No Deco Dive SAFETY STOP (Fig. 34)
Upon ascending to 20 FT (6 M) on any No Decompression dive
in which Depth exceeded 30 FT (9 M), a Safety Stop screen will
appear displaying a recommended Stop at 15 FT (4.5 M) with a
3 minute Countdown Timer that counts down from 03:00 to
0:00 (min:sec).
The Safety Stop will be displayed until the countdown times out,
or you descend below 30 FT (9 M) during the countdown, or
you surface during the countdown.
• Like the Deep Stop, there is no Penalty for surfacing prior to
completing the Safety Stop.
• There is no Preview screen associated with the Safety Stop.
Safety Stop Main display information includes Dive Time Remain-
ing with Mode icon, Stop Depth (15 FT or 4.5 M), STOP bar
icon, Countdown Timer, Current Depth, and applicable bar
graphs.
• Alternate displays are similar to those previously described
for the Deep Stop.
Fig. 34 - NO DECO SAFETY
STOP MAIN
37
DECOMPRESSION DIVE MODE
The Element is designed to help you by providing a representa-
tion of how close you are to entering decompression. Decom-
pression Dive Mode activates when theoretical No Decompres-
sion time/depth limits are exceeded.
Upon entering Decompression Mode, the Mode icon will change
from No Deco to Deco (Fig. 35a).
• The UP Arrow and Deco STOP bar icons will flash until you
are within 10 FT (3 M) of, and below, the required Stop
Depth, then both arrow icons and the bar icon appear solid.
To fulfill your decompression obligation, you should make a safe
controlled ascent to a depth (Fig. 36a) slightly deeper than, or
equal to, the required Stop Depth indicated (Fig. 36b) and
decompress for the Stop Time indicated (Fig. 36c).
Total Ascent Time (Fig. 36d) includes Stop Times for all required
decompression ceilings and vertical Ascent Time calculated at
60 FPM (18 MPM) for depths deeper than 60 FT (18 M), and
30 FPM (9 MPM) for depths of 60 FT (18 M) and shallower.
Fig. 36 - DECO STOP MAIN
Fig. 35 - ENTRY into DECO
a
b
c
a
d
Dostları ilə paylaş: |