28
i
EN
1. Key to Symbols
Danger of fatal electric shock.
This sign warns of danger when working on electrical connections,
components etc. It requires that safety precautions be taken to protect
the health and life of the person concerned.
This concerns your safety.
Please pay particular attention to and carefully follow all instructions
with this symbol.
NOTE/IMPORTANT/ATTENTION
This is to draw your attention to information which works is important
to ensure trouble-free operation.
Please read the operating instructions for an external device des-
cribed at this point, (e. g. a tubular motor).
29
i
EN
2. General safety instructions
All work performed on electrical equipment is associated with
a risk of electric shock and electrocution.
◆
The electrical connection and all work on electrical systems must
only be carried out by a qualified electrician (see chapter 10. - 10.2).
◆
Carry out all installation and connection work only in an isolated,
deenergised state.
The use of defective equipment can lead to personal injury
and damage to property (electric shocks, short circuiting).
◆
Never use defective or damaged equipment.
◆
Check that the DuoFern Connect actuator is intact.
◆
Please contact our Customer Service department (see page 48)
in the event of faults or damage to the actuator.
30
i
EN
3. Correct usage
Only use the DuoFern Connect actuator for the control of:
◆
Roller shutters and Sun shading systems
◆
Blinds and external Venetian blinds
Operating conditions
◆
The installation and operation of the DuoFern radio system and
its components is only permitted for those systems and devices
where a malfunction in the transmitter or receiver would not
cause a danger to persons or property or where this risk is already
covered by other safety equipment.
◆
For the electrical connection a 230 V / 50 Hz power supply, to-
gether with a site-provided isolating device (fuse), must be avail-
able at the installation site.
IMPORTANT
Radio systems which transmit on the same frequency can cause
interference.
4. Incorrect use
Never use the DuoFern radio system and its components (e. g.
DuoFern Connect actuator) for remote control of devices and systems
with heightened safety-relevant requirements or a heightened risk
of accident. Such use would require additional safety equipment.
Observe the respective statutory regulations for the installation of
such systems.
i
31
i
EN
5. General view
Drive
Type plate
Mains
(230 V / 50 Hz)
Safety
clip
Fastening
lug
Connect surface /
Disconnect surface /
Status LED
NOTE
Log on/off to/from DuoFern transmitters, s. page 42.
SET Magnet
32
i
EN
6. Brief description
The DuoFern Connect actuator can be used to equip drives for
blinds, external Venetian blinds and roller shutters with DuoFern
radio technology.
As soon as you integrate your DuoFern Connect actuator into a
DuoFern radio network, you can make use of many functions offered
by the corresponding DuoFern controllers in combination with the
connected drive.
The DuoFern actuators and transmitters must be connected
to the DuoFern network.
In order to make use of the corresponding controllers (e.g. DuoFern
manual transmitter Standard), you must first connect the DuoFern
Connect actuator with the DuoFern network. Use the enclosed SET
magnet to switch the actuator to connect and disconnect mode
(see page 42).
NOTE
A detailed description of the various functions, settings and pos-
sible combinations for DuoFern systems can be obtained under:
http://www.rademacher.de/duofern.
33
i
EN
DuoFern HomePilot®
DuoFern environmental sensor
DuoFern manual central operating unit
* WR ConfigTool with DuoFern manual central operating unit
RolloTron Comfort DuoFern / Troll Comfort DuoFern
DuoFern Standard manual transmitter
DuoFern Wall controller
Function
Value-
range
Factory-
setting
1. Manual control
Up / Stop / Down
-
●
●
●
●
●
2. Direct drive to a %-Position
0 % - 100 %
-
●
3. Manual operation on / off
on / off
off
●
●
●
4. Timer on / off
on / off
on
●
●
●
5. Random function
-
-
●
●
6. Automatic dawn function
-
-
●
●
●
●
7. Automatic dawn function on / off
on / off
off
●
●
●
8. Automatic dusk function
-
-
●
●
●
●
9. Automatic dusk function on / off
on / off
off
●
●
●
10. Solar program
-
-
●
●
11. Automatic solar function on / off
on / off
off
●
●
●
12. Sun position
0 % -100 %
50 %
●
●
●
13. Wind program
-
-
●
14. Automatic wind function on / off
on / off
off
●
●
●
15. Direction of rotation for wind
Up / Down
Up
●
●
●
16. Rain program
-
-
●
17. Automatic rain function on / off
on / off
off
●
●
●
18. Direction of rotation for rain
Up / Down
Up
●
●
●
19. Runtime
2 s – 150 s
150 s
●
●
●
20. Ventilationposition function on / off
on / off
off
●
●
●
21. Ventilationposition
1 % - 99 %
80 %
●
●
●
22. Direction reversal
on / off
off
●
●
●
●
●
23. Connection test
-
-
●
●
24. Connecting via radio code
-
-
●
●
●
7. Functional characteristics