De duoFern Connect Aktor



Yüklə 253,42 Kb.
Pdf görüntüsü
səhifə7/8
tarix22.11.2017
ölçüsü253,42 Kb.
#11710
1   2   3   4   5   6   7   8

28

i

EN

1.  Key to Symbols

Danger of fatal electric shock.

This sign warns of danger when working on electrical connections, 

components etc. It requires that safety precautions be taken to protect 

the health and life of the person concerned.



This concerns your safety.

Please pay particular attention to and carefully follow all instructions 

with this symbol.

NOTE/IMPORTANT/ATTENTION

This is to draw your attention to information which works is important 

to ensure trouble-free operation.

Please read the operating instructions for an external device des-

cribed at this point, (e. g. a tubular motor).



29

i

EN

2.  General safety instructions

All work performed on electrical equipment is associated with 

a risk of electric shock and electrocution.

 



 The electrical connection and all work on electrical systems must 

only be carried out by a qualified electrician (see chapter 10. - 10.2).

 



 Carry out all installation and connection work only in an isolated, 



deenergised state.

The use of defective equipment can lead to personal injury 

and damage to property (electric shocks, short circuiting).

 



Never use defective or damaged equipment.

 



 Check that the DuoFern Connect actuator is intact.

 



 Please contact our Customer Service department (see page 48) 

in the event of faults or damage to the actuator.




30

i

EN

3.  Correct usage

Only use the DuoFern Connect actuator for the control of:

 



 Roller shutters and Sun shading systems



 

 Blinds and external Venetian blinds



Operating conditions

 



The installation and operation of the DuoFern radio system and 

its components is only permitted for those systems and devices 

where a malfunction in the transmitter or receiver would not 

cause a danger to persons or property or where this risk is already 

covered by other safety equipment.

 



 For the electrical connection a 230 V / 50 Hz power supply, to- 

gether with a site-provided isolating device (fuse), must be avail-

able at the installation site.

IMPORTANT

Radio systems which transmit on the same frequency can cause 

interference.

4.  Incorrect use

Never use the DuoFern radio system and its components (e. g.  

DuoFern Connect actuator) for remote control of devices and systems 

with heightened safety-relevant requirements or a heightened risk 

of accident. Such use would require additional safety equipment. 

Observe the respective statutory regulations for the installation of 

such systems.

i



31

i

EN

5.  General view

Drive


Type plate

Mains  


(230 V / 50 Hz)

Safety  


clip

Fastening  

lug

Connect surface / 



Disconnect surface / 

Status LED



NOTE

Log on/off to/from DuoFern transmitters, s. page 42.

SET Magnet



32

i

EN

6.  Brief description

The DuoFern Connect actuator can be used to equip drives for 

blinds, external Venetian blinds and roller shutters with DuoFern 

radio technology.

As soon as you integrate your DuoFern Connect actuator into a  

DuoFern radio network, you can make use of many functions offered 

by the corresponding DuoFern controllers in combination with the 

connected drive. 



The DuoFern actuators and transmitters must be connected 

to the DuoFern network.

In order to make use of the corresponding controllers (e.g. DuoFern 

manual transmitter Standard), you must first connect the DuoFern 

Connect actuator with the DuoFern network. Use the enclosed SET 



magnet to switch the actuator to connect and disconnect mode 

(see page 42). 



NOTE

A detailed description of the various functions, settings and pos-

sible combinations for DuoFern systems can be obtained under:  

http://www.rademacher.de/duofern.



33

i

EN

DuoFern HomePilot®

DuoFern environmental sensor

DuoFern manual central operating unit

 * WR ConfigTool with DuoFern manual central operating unit

RolloTron Comfort DuoFern / Troll Comfort DuoFern

DuoFern Standard manual transmitter  

DuoFern Wall controller

Function

Value- 

range

Factory-

setting

1.   Manual control

Up / Stop / Down

-





2.   Direct drive to a %-Position

0 % - 100 %

-



3.    Manual operation on / off

on / off


off



4.   Timer on / off

on / off

on



5.   Random function



-

-



6.   Automatic dawn function

-

-





7.   Automatic dawn function on / off

on / off


off



8.   Automatic dusk function

-

-





9.   Automatic dusk function on / off

on / off


off



10.   Solar program

-

-



11.   Automatic solar function on / off

on / off

off




12.   Sun position

0 % -100 %

50 %





13.   Wind program

-

-



14.   Automatic wind function on / off

on / off


off



15.   Direction of rotation for wind

Up / Down

Up



16.   Rain program



-

-



17.   Automatic rain function on / off

on / off


off



18.   Direction of rotation for rain

Up / Down

Up



19.   Runtime



2 s – 150 s

150 s




20.   Ventilationposition function on / off

on / off


off



21.   Ventilationposition 

1 % - 99 %

80 %




22.   Direction reversal

on / off


off





23.   Connection test

-

-



24.   Connecting via  radio code



-

-





7.  Functional characteristics