Chapter 8
|
Data Transfer and Software Updates
Meter Calibration Data from GETCAL # Command
Mode
Printed Format
pH
Meter Type, Meter Serial Number, Meter Software Revision, Channel Number, Electrode
ID, Module Serial Number, Method Number, Calibration Date, Calibration Time, User ID,
Total Calibration Points,
(repeated for each calibration point) Calibration Point Number, pH Unit, pH Value, mV
Unit, mV Value, Temperature Value, Temperature Unit, Calibration Type,
(repeated for each point-to-point segment) Segment Number, Slope Value, Slope Unit,
(repeated for each point-to-point segment) Segment Number, Offset Value, Offset Unit,
Average Slope Value, Average Slope Unit, Calibration Log Number
Example (5 point calibration): VERSA STAR, V00000, 2.73, Ch-1, SENSOR-01,
VA12345, M-101, 15-03-14, 1:30:30 PM, USER-01, 5, 1, pH, 1.678, mV, 290.4, 25.0, C
(MAN), Auto, 2, pH, 4.01, mV, 174.3, 25.0, C (MAN), Auto, 3, pH, 6.997, mV, 0.0, 25.0, C
(MAN), Auto, 4, pH, 10.013, mV, -173.7, 25.0, C (MAN), Auto, 5, pH, 12.46, mV, -289.5,
25.0, C (MAN), Auto, 1, -49.8, mV, 2, -58.4, mV, 3, -57.6, mV, 4, -47.3, mV, 1, 25.4, mV,
2, -0.2, mV, 3, -0.2, mV, 4, -31.1, mV, 90.0, %, 101
RmV
Meter Type, Meter Serial Number, Meter Software Revision, Channel Number, Electrode
ID, Module Serial Number, Method Number, Calibration Date, Calibration Time, User ID,
Relative mV Value, Relative mV Unit, Raw mV Value, Raw mV Unit, Temperature Value,
Temperature Unit, Relative mV Offset Value, Relative mV Offset Unit, Calibration Log
Number
Example: VERSA STAR, V00000, 2.73, Ch-1, SENSOR-01, VA12345, M-101, 15-03-14,
1:30:30 PM, USER-01, 199.8, RmV, 199.7, mV, 25.0, C (MAN), 0.1, mV, 101
ORP
Meter Type, Meter Serial Number, Meter Software Revision, Channel Number, Electrode
ID, Module Serial Number, Method Number, Calibration Date, Calibration Time, User ID,
ORP Value, ORP Unit, Raw mV Value, Raw mV Unit, Temperature Value, Temperature
Unit, ORP Offset Value, ORP Offset Unit, Calibration Log Number
Example: VERSA STAR, V00000, 2.73, Ch-1, SENSOR-01, VA12345, M-101, 15-03-14,
1:30:30 PM, USER-01, 419.5, RmV, 199.8, mV, 25.0, C (MAN), 219.7, mV, 101
ISE
Meter Type, Meter Serial Number, Meter Software Revision, Channel Number, Electrode
ID, Electrode Type, Module Serial Number, Method Number, Calibration Date,
Calibration Time, User ID, Total Calibration Points,
(repeated for each calibration point) Calibration Point Number, Concentration Value,
Concentration Unit, mV Value, mV Unit, Temperature Value, Temperature Unit,
Calibration Type,
(repeated for each point-to-point segment) Segment Number, Slope Value, Slope Unit,
(repeated for each point-to-point segment) Segment Number, Offset Value, Offset Unit,
Average Slope Value, Average Slope Unit, Blank Function, Blank Value, Blank Unit,
Calibration Log Number
Example (5 point calibration): VERSA STAR, V00000, 2.73, Ch-2, SENSOR-02, F-,
VA12345, M-201, 15-03-14, 1:30:30 PM, USER-01, 5, 1, 0.1, ppm, 174.2, mV, 25.0, C
(MAN), Manual, 2, 1, ppm, 116.2, mV, 25.0, C (MAN), Manual, 3, 10, ppm, 58.0, mV,
25.0, C (MAN), Manual, 4, 100, ppm, 0.0, mV, 25.0, C (MAN), Manual, 5, 1000, ppm, -
57.8, mV, 25.0, C (MAN), Manual, 1, -58.0, mV/dec, 2, -58.2, mV/dec, 3, -58.0, mV/dec,
4, -57.8, mV/dec, 1, 116.2, mV, 2, 116.2, mV, 3, 116.0, mV, 4, 115.6, mV, -58.0,
mV/dec, 0, 0.000, ppm, 201
Thermo Scientific
Orion V
ERSA
S
TAR
Meter User Manual
|
85
Chapter 8
|
Data Transfer and Software Updates
Mode
Printed Format
Incremental
Technique
(Single
Known
Addition and
Single
Known
Subtraction)
Meter Type, Meter Serial Number, Meter Software Revision, Channel Number, Electrode
ID, Electrode Type, Module Serial Number, Method Number, Calibration Date,
Calibration Time, User ID, Incremental Type, Slope Value, Slope Unit, Sample Volume
Value, Sample Volume Unit, Total Volume Value, Total Volume Unit, Standard
Concentration Value, Standard Concentration Unit, Reaction Ratio ( known subtraction
only), Measured Sample Value, Measured Sample Unit, Standard Volume Value,
Standard Volume Unit, Measured Sample and Standard Value, Measured Sample and
Standard Unit, Temperature Value, Temperature Unit, Calculated Concentration Value,
Calculated Concentration Unit, Calibration Log Number
Example: VERSA STAR, V00000, 2.73, Ch-2, SENSOR-02, F-, VA12345, M-201, 15-03-
14, 1:30:30 PM, USER-01, Single Known Addition, -59.2, mV/dec, 100.000, mL, 102.000,
mL, 100.000, ppm, 0.0, mV, 1.000, mL, -57.8, mV, 25.0, C (MAN), 0.117, ppm, 201
Example: VERSA STAR, V00000, 2.73, Ch-2, SENSOR-02, F-, VA12345, M-201, 15-03-
14, 1:30:30 PM, USER-01,Single Known Subtraction, -59.2, mV/dec, 100.000, mL,
102.000, mL, 0.100, molar, 0.500, 0.0, mV, 5.000, mL, 58.0, mV, 25.0, C (MAN),
0.00281, molar, 202
Incremental
Technique
(Double
Known
Addition and
Double
Known
Subtraction)
Meter Type, Meter Serial Number, Meter Software Revision, Channel Number, Electrode
ID, Electrode Type, Module Serial Number, Method Number, Calibration Date,
Calibration Time, User ID, Incremental Type, Slope Value, Slope Unit, Sample Volume
Value, Sample Volume Unit, Total Volume Value, Total Volume Unit, Standard
Concentration Value, Standard Concentration Unit, Reaction Ratio (known subtraction
only), Measured Sample Value, Measured Sample Unit, First Standard Volume Value,
First Standard Volume Unit, Measured Sample and First Standard Value, Measured
Sample and First Standard Unit, Second Standard Volume Value, Second Standard
Volume Unit, Measured Sample and Second Standard Value, Measured Sample and
Second Standard Unit, Temperature Value, Temperature Unit, Calculated Concentration
Value, Calculated Concentration Unit, Calibration Log Number
Example: VERSA STAR, V00000, 2.73, Ch-2, SENSOR-02, F-, VA12345, M-201, 15-03-
14, 1:30:30 PM, USER-01, Double Known Addition, -58.0, mV/dec, 100.000, mL,
102.000, mL, 100.000, ppm, 0.0, mV, 1.000, mL, -17.8, mV, 10.000, mL, -63.3, mV, 25.0,
C (MAN), 1.040, ppm, 203
Example: VERSA STAR, V00000, 2.73, Ch-2, SENSOR-02, F-, VA12345, M-201, 15-03-
14, 1:30:30 PM, USER-01, Double Known Subtraction, -58.0, mV/dec, 100.000, mL,
102.000, mL,0.100, molar, 0.500, 0.0, mV, 1.000, mL, 8.9, mV, 10.000, mL, 32.3, mV,
25.0, C (MAN), 0.00140, molar, 204
Conductivity
Meter Type, Meter Serial Number, Meter Software Revision, Channel Number, Electrode
ID, Module Serial Number, Method Number, Calibration Date, Calibration Time, User ID,
Total Calibration Points,
(repeated for each calibration point) Calibration Point Number, Conductivity Value,
Conductivity Unit, Conductance Value, Conductance Unit, Temperature Value,
Temperature Unit, Calibration Type,
(repeated for each calibration point) Calibration Point Number, Cell Constant Value, Cell
Constant Unit,
Average Cell Constant Value, Average Cell Constant Unit, Calibration Log Number
Example (1 point calibration): VERSA STAR, V00000, 2.73, Ch-3, SENSOR-03,
VA12345, M-301, 15-03-14, 1:30:30 PM, USER-01, 1, 1, 100.0, uS/cm, 99.98, uS, 25.0,
C (MAN), Auto, 1, 1.0010, /cm, 1.0010, /cm, 1, 0.00, uS/cm, 301
86
|
Orion V
ERSA
S
TAR
Meter User Manual
Thermo Scientific
Dostları ilə paylaş: |