Orion versa star user Manual


   |    Data Transfer and Software Updates



Yüklə 6,2 Kb.
Pdf görüntüsü
səhifə31/44
tarix05.01.2018
ölçüsü6,2 Kb.
#19795
1   ...   27   28   29   30   31   32   33   34   ...   44

Chapter 8  
|
  
Data Transfer and Software Updates 
Mode 
Printed Format 
ORP 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel 
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, ORP Value, 
ORP Unit, Raw mV Value, Raw mV Unit, Temperature ValueTemperature Unit, Method 
Number 
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-1, SENSOR-01, 1, 
USER-01, VA12345, ORP, 0.0, ORP, 0.0, mV, 25.0, C (MAN), M101  
ISE 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel 
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, Electrode Type, 
ISE Value, ISE Unit, mV Value, mV Unit, Temperature Value, Temperature Unit, Average 
Slope Value, Average Slope Unit, Method Number 
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-2, SENSOR-02, 1, 
USER-01, VA12345, ISE, F-, 1.00, ppm, 0.0, mV, 25.0, C (MAN), 59.2, mV/dec, M201 
 
Conductivity 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel 
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, Conductivity 
Value, Conductivity Unit, Conductance Value, Conductance Unit, Temperature Value, 
Temperature Unit, Temperature Coefficient Value, Temperature Coefficient Unit
Temperature Reference Value, Temperature Reference Unit, Cell Constant Value, Cell 
Constant Unit, Method Number 
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-3, SENSOR-03, 1, 
USER-01, VA12345, Conductivity, 100.0, uS/cm, 99.982, uS, 25.0, C (ATC), 2.1, %/C, 
25.0, C, 1.0010, /cm, M301  
TDS 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel 
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, TDS Value, 
TDS Unit, Conductance Value, Conductance Unit, Temperature Value, Temperature Unit, 
Temperature Coefficient Value, Temperature Coefficient Unit, Temperature Reference 
Value, Temperature Reference Unit, TDS Factor, Cell Constant Value, Cell Constant Unit, 
Method Number 
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-3, SENSOR-03, 1, 
USER-01, VA12345, TDS, 49.04, ppm, 99.982, uS, 25.0, C (ATC), 2.1, %/C, 25.0, C, 
0.49, 1.0010, /cm, M301  
Salinity 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel 
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, Salinity Value, 
Salinity Unit, Conductance Value, Conductance Unit, Temperature Value, Temperature 
Unit, Salinity Type, Temperature Reference Value, Temperature Reference Unit, Cell 
Constant Value, Cell Constant Unit, Method Number 
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-3, SENSOR-03, 1, 
USER-01, VA12345, Salinity, 0.052, psu, 99.982, uS, 25.0, C (ATC), 15.0, C, 1.0010, /cm, 
M301  
Resistivity 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel 
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, Resistivity 
Value, Resistivity Unit, Conductance Value, Conductance Unit, Temperature Value, 
Temperature Unit, Temperature Coefficient Value, Temperature Coefficient Unit, 
Temperature Reference Value, Temperature Reference Unit, Cell Constant Value, Cell 
Constant Unit, Method Number 
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-3, SENSOR-03, 1, 
USER-01, VA12345, Resistivity, 9.992, KOhm-cm, 99.982, uS, 25.0, C (ATC), 2.1, %/C, 
25.0, C, 1.0010, /cm, M301  
Thermo Scientific 
Orion V
ERSA 
S
TAR
 Meter User Manual  
|
  
83
 


Chapter 8  
|
  
Data Transfer and Software Updates 
Mode 
Printed Format 
DO % 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel 
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, DO Saturation 
Value, DO Saturation Unit, DO Concentration Value, DO Concentration Unit, Current 
Value, Current Unit, Solution Temperature Value, Solution Temperature Unit, Membrane 
Temperature Value, Membrane Temperature Unit, Barometric Pressure Value, Barometric 
Pressure Unit, Salinity Correction Value in ppt, Slope Value, Slope Unit, Method Number 
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-4, SENSOR-04, 1, 
USER-01, VA12345, DO, 102.0, %, 8.59, mg/L, 1331.38, nA, 24.5, C (ATC), 24.6, C 
(ATC), 760.2, mmHg, 0.1, 11.8, nA/%sat, M401  
DO mg/L 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel 
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, DO 
Concentration Value, DO Concentration Unit, DO Saturation Value, DO Saturation Unit, 
Current Value, Current Unit, Solution Temperature Value, Solution Temperature Unit, 
Membrane Temperature Value, Membrane Temperature Unit, Barometric Pressure Value, 
Barometric Pressure Unit, Salinity Correction Value in ppt, Slope Value, Slope Unit, 
Method Number 
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-4, SENSOR-04, 1, 
USER-01, VA12345, DO, 8.59, mg/L, 102.0, %, 1331.38, nA, 24.5, C (ATC), 24.6, C 
(ATC), 760.2, mmHg, 0.1, 11.8, nA/%sat, M401  
RDO % 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel 
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, RDO Saturation 
Value, RDO Saturation Unit, RDO Concentration Value, RDO Concentration Unit, Partial 
Pressure in Torr, Solution Temperature Value, Solution Temperature Unit, Barometric 
Pressure Value, Barometric Pressure Unit, Salinity Correction Value in ppt, Slope Value, 
Slope Unit, Method Number 
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-4, SENSOR-04, 1, 
USER-01, VA12345, RDO, 102.0, %, 8.59, mg/L, 150.052, 24.3, C (ATC), 760.2, mmHg, 
0.1, 1.6, Torr/%Sat, M401  
RDO mg/L 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel 
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, RDO 
Concentration Value, RDO Concentration Unit, RDO Saturation Value, RDO Saturation 
Unit, Partial Pressure in Torr, Solution Temperature Value, Solution Temperature Unit, 
Barometric Pressure Value, Barometric Pressure Unit, Salinity Correction Value in ppt, 
Slope Value, Slope Unit, Method Number 
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-4, SENSOR-04, 1, 
USER-01, VA12345, RDO, 8.59, mg/L, 102.0, %, 150.052, 24.3, C (ATC), 760.2, mmHg, 
0.1, 1.6, Torr/%Sat, M401  
Multiple 
Channels 
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time  
followed by the measurement data for each channel as shown above 
 
 
 
84  
|
  
Orion V
ERSA 
S
TAR
 Meter User Manual 
Thermo Scientific 


Yüklə 6,2 Kb.

Dostları ilə paylaş:
1   ...   27   28   29   30   31   32   33   34   ...   44




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©genderi.org 2024
rəhbərliyinə müraciət