Chapter 8
|
Data Transfer and Software Updates
Mode
Printed Format
ORP
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, ORP Value,
ORP Unit, Raw mV Value, Raw mV Unit, Temperature Value, Temperature Unit, Method
Number
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-1, SENSOR-01, 1,
USER-01, VA12345, ORP, 0.0, ORP, 0.0, mV, 25.0, C (MAN), M101
ISE
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, Electrode Type,
ISE Value, ISE Unit, mV Value, mV Unit, Temperature Value, Temperature Unit, Average
Slope Value, Average Slope Unit, Method Number
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-2, SENSOR-02, 1,
USER-01, VA12345, ISE, F-, 1.00, ppm, 0.0, mV, 25.0, C (MAN), 59.2, mV/dec, M201
Conductivity
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, Conductivity
Value, Conductivity Unit, Conductance Value, Conductance Unit, Temperature Value,
Temperature Unit, Temperature Coefficient Value, Temperature Coefficient Unit,
Temperature Reference Value, Temperature Reference Unit, Cell Constant Value, Cell
Constant Unit, Method Number
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-3, SENSOR-03, 1,
USER-01, VA12345, Conductivity, 100.0, uS/cm, 99.982, uS, 25.0, C (ATC), 2.1, %/C,
25.0, C, 1.0010, /cm, M301
TDS
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, TDS Value,
TDS Unit, Conductance Value, Conductance Unit, Temperature Value, Temperature Unit,
Temperature Coefficient Value, Temperature Coefficient Unit, Temperature Reference
Value, Temperature Reference Unit, TDS Factor, Cell Constant Value, Cell Constant Unit,
Method Number
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-3, SENSOR-03, 1,
USER-01, VA12345, TDS, 49.04, ppm, 99.982, uS, 25.0, C (ATC), 2.1, %/C, 25.0, C,
0.49, 1.0010, /cm, M301
Salinity
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, Salinity Value,
Salinity Unit, Conductance Value, Conductance Unit, Temperature Value, Temperature
Unit, Salinity Type, Temperature Reference Value, Temperature Reference Unit, Cell
Constant Value, Cell Constant Unit, Method Number
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-3, SENSOR-03, 1,
USER-01, VA12345, Salinity, 0.052, psu, 99.982, uS, 25.0, C (ATC), 15.0, C, 1.0010, /cm,
M301
Resistivity
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, Resistivity
Value, Resistivity Unit, Conductance Value, Conductance Unit, Temperature Value,
Temperature Unit, Temperature Coefficient Value, Temperature Coefficient Unit,
Temperature Reference Value, Temperature Reference Unit, Cell Constant Value, Cell
Constant Unit, Method Number
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-3, SENSOR-03, 1,
USER-01, VA12345, Resistivity, 9.992, KOhm-cm, 99.982, uS, 25.0, C (ATC), 2.1, %/C,
25.0, C, 1.0010, /cm, M301
Thermo Scientific
Orion V
ERSA
S
TAR
Meter User Manual
|
83
Chapter 8
|
Data Transfer and Software Updates
Mode
Printed Format
DO %
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, DO Saturation
Value, DO Saturation Unit, DO Concentration Value, DO Concentration Unit, Current
Value, Current Unit, Solution Temperature Value, Solution Temperature Unit, Membrane
Temperature Value, Membrane Temperature Unit, Barometric Pressure Value, Barometric
Pressure Unit, Salinity Correction Value in ppt, Slope Value, Slope Unit, Method Number
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-4, SENSOR-04, 1,
USER-01, VA12345, DO, 102.0, %, 8.59, mg/L, 1331.38, nA, 24.5, C (ATC), 24.6, C
(ATC), 760.2, mmHg, 0.1, 11.8, nA/%sat, M401
DO mg/L
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, DO
Concentration Value, DO Concentration Unit, DO Saturation Value, DO Saturation Unit,
Current Value, Current Unit, Solution Temperature Value, Solution Temperature Unit,
Membrane Temperature Value, Membrane Temperature Unit, Barometric Pressure Value,
Barometric Pressure Unit, Salinity Correction Value in ppt, Slope Value, Slope Unit,
Method Number
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-4, SENSOR-04, 1,
USER-01, VA12345, DO, 8.59, mg/L, 102.0, %, 1331.38, nA, 24.5, C (ATC), 24.6, C
(ATC), 760.2, mmHg, 0.1, 11.8, nA/%sat, M401
RDO %
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, RDO Saturation
Value, RDO Saturation Unit, RDO Concentration Value, RDO Concentration Unit, Partial
Pressure in Torr, Solution Temperature Value, Solution Temperature Unit, Barometric
Pressure Value, Barometric Pressure Unit, Salinity Correction Value in ppt, Slope Value,
Slope Unit, Method Number
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-4, SENSOR-04, 1,
USER-01, VA12345, RDO, 102.0, %, 8.59, mg/L, 150.052, 24.3, C (ATC), 760.2, mmHg,
0.1, 1.6, Torr/%Sat, M401
RDO mg/L
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time, Channel
Number, Electrode ID, Sample ID, User ID, Module Serial Number, Mode, RDO
Concentration Value, RDO Concentration Unit, RDO Saturation Value, RDO Saturation
Unit, Partial Pressure in Torr, Solution Temperature Value, Solution Temperature Unit,
Barometric Pressure Value, Barometric Pressure Unit, Salinity Correction Value in ppt,
Slope Value, Slope Unit, Method Number
Example: VERSA STAR, V00000, 2.73, 15-03-14, 1:30:30 PM, Ch-4, SENSOR-04, 1,
USER-01, VA12345, RDO, 8.59, mg/L, 102.0, %, 150.052, 24.3, C (ATC), 760.2, mmHg,
0.1, 1.6, Torr/%Sat, M401
Multiple
Channels
Meter Type, Meter Serial Number, Meter Software Revision, Date, Time
followed by the measurement data for each channel as shown above
84
|
Orion V
ERSA
S
TAR
Meter User Manual
Thermo Scientific
Dostları ilə paylaş: |