Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


NOTE A remote hand-held switching device, an external interconnection between two parts of a tool and a cord



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə129/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   125   126   127   128   129   130   131   132   ...   138
NOTE A remote hand-held switching device, an external interconnection between two parts of a tool and a cord
connecting an accessory to the tool or to a separate signalling circuit are examples of interconnecting cords.
L.5 General conditions for the tests
L.5.101 Unless otherwise specified, a fully charged battery pack shall be used for each test.
L.5.102 When measuring voltage, the peak value of any superimposed ripple exceeding 10% of the
average value shall be included. Transient voltages are ignored, such as a temporary increase above
nominal, such as after the battery pack is removed from the charger.
L.7 Classification
L.7.1 This clause applies except that class III tools are not considered in this annex.
L.8 Marking and Instructions
L.8.1 The first paragraph of this clause is replaced by the following:
Non-isolated sources that can supply a tool or tools that can be supplied directly from the mains shall be
marked with the following. In the case of tools supplied directly from the mains, these markings shall
include those for both mains and battery operation:
– rated voltage(s) or rated voltage range(s), in volts;
– symbol for nature of supply;
– rated input, in watts, or rated current in amperes,
– name or trade mark or identification mark of the manufacturer or responsible vendor;
– model or type reference;
– symbol for class II construction, for class II tools only;
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
133
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


– manufacturer’s address or country of origin;
– any mandatory mark showing compliance with legislation by reference to this standard.
Compliance is checked by inspection.
L.8.1.101 Tools, other than those that can be supplied directly from the mains, and detachable or
separable battery packs shall be marked with:
– rated voltage(s) or rated voltage range(s), in volts;
– symbol for nature of supply;
– name or trade mark or identification mark of the manufacturer or responsible vendor;
– model or type reference.
– manufacturer’s address or country of origin;
– any mandatory mark showing compliance with legislation by reference to this standard.
Additional markings shall not give rise to misunderstanding.
Compliance is checked by inspection.
L.8.12.1 This clause is applicable except as follows
Item 5) Service, is replaced by the following: