L.2 Normative References
This clause is applicable except as follows:
Additional normative reference:
IEC 61558–2–6:1997, Safety of power transformers, power supply units and similar – Part 2: Particular
requirements for safety isolating transformers for general use
L.3 Definitions
For the purpose of this annex, the following definitions apply:
L.3.101 battery pack : assembly of one or more cells intended to provide electrical current to the tool
L.3.101.1 detachable battery pack : a battery pack which is contained in a separate enclosure from the
battery tool and is intended to be removed from the tool for charging purposes.
L.3.101.2 integral battery pack : A battery pack which is contained within the battery tool and is not
removed from the battery tool for charging purposes. A battery pack that is to be removed from the
battery tool for disposal or recycling purposes only is considered to be an integral battery pack.
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
132
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


L.3.101.3 separable battery pack : A battery pack which is contained in a separate enclosure from the
battery tool and is connected to the battery tool by a cord.
L.3.102 fully charged battery pack : A battery pack which has been through at least two discharge and
charge cycles with an interval of at least two hours after each cycle in accordance with the
manufacturer’s instructions.
L.3.103 non-isolated source : A voltage source in which the output is not isolated from the mains
supply by means of a safety isolating transformer as specified
L.3.104 hazardous voltage : A voltage between parts having an average value exceeding 60 V d.c. or
42,4 V peak when the peak to peak ripple exceeds 10% of the average value.
L.3.105 power switch : power switch that controls the primary operating means of the tool.
L.3.106 interconnecting cord : external flexible cord provided as part of a complete tool for purposes