MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
77
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


– glands shall not be used as cord anchorages for power supply cords;
– for class I tools, they are of insulating material or are provided with an insulating lining, if
otherwise an insulation fault on the cord could make accessible metal parts live;
– for class II tools, they are of insulating material, or, if of metal, are insulated from accessible
metal parts by insulation complying with the requirements for supplementary insulation.
If, for type X attachment, the cord anchorage comprises one or more clamping member(s) to which
pressure is applied by means of one or more nuts engaging with studs, which are securely attached to
the tool, the cord anchorage is considered to have one part securely fixed to the tool, even if the clamping
member(s) can be removed from the studs.
If, however, the pressure on the clamping member(s) is applied by means of one or more screws
engaging either with separate nuts, or with a thread in a part which is integral with the tool, the cord
anchorage is not considered to have one part securely fixed to the tool, unless one of the clamping
members itself is fixed to the tool, or the surface of the tool is of insulating material and so shaped that it
is obvious that surface is one of the clamping member(s) (see Figure 6).
Compliance is checked by inspection, and by the test of 24.14 under the following conditions.
The tests are first made with the lightest permissible type of cord of the smallest cross-sectional area
specified in 25.2, and then with the next heavier type of cord of the largest cross-sectional area specified,
unless the tool is so designed that only one type of cord can be fitted.
Tools, for which a specially prepared cord is used, are tested with the cord as delivered.
The conductors are introduced into the terminals, the terminal screws, if any, being tightened just
sufficiently to prevent the conductors from easily changing their position. The cord anchorage is used in
the normal way, the clamping screws, if any, being tightened with a torque equal to two-thirds of that
specified in 27.1.
Screws of insulating material bearing directly on the cord are fastened with two-thirds of the torque
specified in column I of Table 9; the length of the slot in the screw head being taken as the nominal
diameter of the screw.
24.17 For type Y and Z attachments, cord anchorage shall be adequate.
Compliance is checked by the test of 24.14, which is made with the cord as delivered.
24.18 For type X attachment, production methods such as tying the cord into a knot, or tying the ends
with string, are not allowed.
Compliance is checked by inspection.
24.19 For type Y and type Z attachments, the insulated conductors of the supply cord shall be insulated
from accessible metal parts by insulation complying with the requirements for basic insulation for class I
tools, and complying with the requirements for supplementary insulation for class II tools. This insulation
shall consist of:
– a separate insulating lining fixed to the cord anchorage;
– a sleeve or grommet fixed to the cord; or

Yüklə 4,83 Kb.