– for class I tools, the sheath of the sheathed cord.
Compliance is checked by inspection.
24.20 The space for the supply cables or the supply cord provided inside, or as a part of the tool for type
X attachment:
– shall be so designed as to permit checking, before fitting the cover, if any, that the
conductors are correctly connected and positioned;
– shall be so designed that covers, if any, can be fitted without risk of damage to the supply
conductors or their insulation;
– shall be so designed that the uninsulated end of the conductor, should it become free from a
terminal, cannot come into contact with accessible metal parts, unless the cord is provided with
terminations that are unlikely to slip free of the conductor.
Compliance is checked by inspection and, for type X attachment, by an installation test with cables or
flexible cords of the largest cross-sectional area specified in 25.2 and by the following additional test.
For pillar terminals where the conductors are not separately clamped at a distance of 30 mm or less from
the terminal, and for other terminals with screw clamping, the clamping screws or nuts are loosened in
turn. Without removing the conductor from the conductor space, a force of 2 N is applied to the wire in
any direction and adjacent to the terminal, screw or stud. The uninsulated end of the conductor shall not
then come into contact with accessible metal parts or any other metal part connected thereto.
For pillar terminals, where the conductors are separately clamped at a distance of 30 mm or less from the
terminal, the tool is considered to meet the requirement that the uninsulated end of the conductor must
not come into contact with accessible metal parts.
24.21 Appliance inlets shall:
– be so located or enclosed that live parts are not accessible during insertion or removal of the
connector;
– be so placed that the connector can be inserted without difficulty;
– be so placed that, after insertion of the connector, the tool is not supported by the connector
when in any position of normal use on a flat surface.
Compliance is checked by inspection and, with regard to the first requirement, by means of the standard
test finger shown in Figure 1, for tool inlets other than those standardized in IEC 60320.
Tools provided with appliance inlets complying with IEC 60320 are considered to comply with the first
requirement.