Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə87/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   83   84   85   86   87   88   89   90   ...   138
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
79
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


25 Terminals for external conductors
25.1 Tools with type X attachments, except those with specially prepared cord, shall be provided with
terminals in which connection is made by means of screws, nuts, or equally effective devices. Screw type
terminals in accordance with IEC 60998-2-1, screwless terminals in accordance with IEC 60998-2-2 and
clamping units in accordance with IEC 60999-1 are considered to be equally effective devices.
Screws and nuts shall not serve to fix any other component, except that they may also clamp internal
conductors, if these are so arranged that they are unlikely to be displaced when fitting the supply
conductors.
Compliance is checked by inspection.
For tools with type X attachments, soldered connections may be used for the connection of external
conductors, provided that the conductor is so positioned or fixed that reliance is not placed upon the
soldering alone to maintain the conductor in position, unless barriers are provided so that creepage
distances and clearances between live parts and other metal parts cannot be reduced to less than 50 %
of the values specified in 28.1, should the conductor become free at the soldered joint.
For type Y and type Z attachments, soldered, welded, crimped and similar connections may be used for
the connection of external conductors; moreover, for class II tools, the conductor shall be so positioned or
fixed that reliance is not placed upon the soldering, crimping, or welding alone to maintain the conductor
in position, unless barriers are provided so that creepage distances and clearances between live parts and
other metal parts cannot be reduced to less than 50 % of the values specified in 28.1, should the
conductor become free at the soldered or welded joint, or slip out of the crimped connection.
It is not to be expected that two independent fixings will become loose at the same time.
Conductors connected by soldering are not considered to be adequately fixed, unless they are held in
place near to the termination, independently of the solder; but

hooking in

before soldering is, in general,
considered to be a suitable means for maintaining the conductors of a power supply cord other than a
tinsel cord in position, provided the hole through which the conductor is passed is not unduly large.
The terminals of a component (such as a switch) built into the tool – on the assumption that they comply
with the requirements of this clause – may be used as terminals intended for external conductors.
Conductors connected to terminals or terminations by other means are not considered to be adequately
fixed, unless an additional fixing is provided near the terminal or termination; this additional fixing, in the
case of stranded conductors, clamps both the insulation and the conductor.
Compliance is checked by inspection and by measurement.
25.2 Terminals for type X attachment, except those with specially prepared cords, shall allow the
connection of conductors having nominal cross-sectional areas as shown in Table 8, unless the tool is so
designed that only one type of cord can be fitted, in which case the terminals shall be suitable for the
connection of that cord.