26.2DV D1
Modification: Add the following paragraphs:
Quick-connect terminals may be used to terminate or interconnect grounding and bonding
conductors in sizes 18 – 14 AWG under the following conditions:
a) For wire sizes 18 – 16 AWG, the minimum connector and tab width shall be
2.80 mm (0.110 inch); or
b) For wire sizes 14 AWG, the minimum connector and tab width shall be 6.35
mm (0.250 inch).
Quick-connect tabs shall not be less than 0.8 mm (0.032 inch) thick.
Multipin (friction type) insulated connectors shall not be used in equipment grounding
paths unless they are shown to be acceptable for grounding use.
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
83
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


26.3 If detachable parts have an earth connection, this connection shall be made before the
current-carrying connections are established when placing the part in position, and the current-carrying
connections shall be separated before the earth connection is broken when removing the part.
For tools with supply cords, the arrangement of the terminals, or the length of the conductors between the
cord anchorage and the terminals, shall be such that the current-carrying conductors become taut before
the earthing conductor, if the cord slips out of the cord anchorage.
Compliance is checked by inspection and by manual test.
26.4 All parts of the earthing terminal intended for the connection of external conductors shall be such
that there is no risk of corrosion resulting from contact between these parts and the copper of the earthing
conductor, or any other metal in contact with these parts.
Parts which may transmit current in the event of an insulation fault, other than parts of a metal frame or
enclosure, shall be of coated or uncoated metal having adequate resistance to corrosion. If such parts are
of steel, they shall be provided at the essential areas with an electroplated coating having a thickness of
at least 5 µm.
Parts of coated or uncoated metal, which are only intended to provide or to transmit contact pressure,
shall be adequately protected against rusting.
Examples of parts which may transmit current in the event of an insulation fault, and parts which are only
intended to provide or to transmit contact pressure are shown in Figure 8.
If the body of the earthing terminal is a part of a frame or enclosure of aluminium or aluminium alloy,
precautions shall be taken to avoid the risk of corrosion resulting from contact between copper and
aluminium or its alloys.
Parts of copper alloys containing at least 58 % copper for parts that are worked cold, and at least 50 %
copper for other parts, and parts of stainless steel containing at least 13 % chrome, are considered to be
sufficiently resistant to corrosion. Parts subjected to a treatment such as chromate conversion coating are
in general not considered to be adequately protected against corrosion, but they may be used to provide
or to transmit contact pressure.
The essential areas of steel parts are, in particular, those transmitting current. In evaluating such areas,
the thickness of the coating in relation to the shape of the part has to be taken into account. In case of
doubt, the thickness of the coating is measured as described in ISO 2178 or in ISO 1463.
Compliance is checked by inspection, by measurement, by manual test, and by the test of 30.1.

Yüklə 4,83 Kb.

Dostları ilə paylaş:
1   ...   87   88   89   90   91   92   93   94   ...   138




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©genderi.org 2024
rəhbərliyinə müraciət

    Ana səhifə