1 of 10 Revision Date: 10/12/21 Specific Procedures for Use of Self-Contained Breathing Apparatus


EHS Equipment Specifications ......................................................................................................7



Yüklə 306,38 Kb.
Pdf görüntüsü
səhifə2/10
tarix11.10.2023
ölçüsü306,38 Kb.
#127266
1   2   3   4   5   6   7   8   9   10
ProcedureSCBA

EHS Equipment Specifications ......................................................................................................7
 
SCBA INSPECTION LOG .................................................................................................................8
 
SCBA AIR CYLINDER TANK INSPECTION LOG ..................................................................................9
 
Scott Air-Pak 75 SCBA INSPECTION LOG ...................................................................................... 10
 
Scott AIR-PAK 75 4.5 ...................................................................................................................... 10 
Inspection Form ............................................................................................................................. 10 
Pass ........................................................................................................................................................ 10
 
Fail .......................................................................................................................................................... 10
 
It should be noted that SCBAs will provide the highest level of respiratory protection and it is important 
to use the appropriate protective clothing to complete the ensemble. In particular, full body protection 
is needed in emergency situations where gas or vapor is present that can be absorbed through the skin 
or cause deterioration of the SCBA components. 


Procedure for Use of SCBA 
Back to Table of Contents
 
Page 
2
of 
10
Revision Date: 10/12/21 
Selection and Use 
SCBAs will be used during certain maintenance activities or operations where other respirator 
protection is not adequate based on the toxicity and warning properties of the hazardous materials 
(such as Isocyanates), or when responding to emergencies where: 

The atmosphere presents an oxygen deficiency (less than 19.5% oxygen); 

There is a concentration of a hazardous chemical that is immediately dangerous to life or health 
(IDLH); 

Where the hazardous substance, in certain atmospheres, lacks an adequate warning property (odor 
or taste), or the identity or quantity of the substance is unknown and in the professional judgment 
of the emergency responder, air concentrations may exceed that which could be adequately 
protected from use of 
negative pressure respirators
; and 

It is deemed necessary by the emergency response personnel. 
Normally the determination to use SCBA in an emergency shall be made by key facility personnel who 
have attended EHS Emergency Response Training or trained EHS staff. 
When such an emergency arises, authorized University personnel to affect rescue or mitigate the 
release of a hazardous material will wear SCBAs. All SCBA units used for emergency purposes will be 
NIOSH approved, open circuit/pressure demand, with a full-facepiece. 