1 of 10 Revision Date: 10/12/21 Specific Procedures for Use of Self-Contained Breathing Apparatus



Yüklə 306,38 Kb.
Pdf görüntüsü
səhifə7/10
tarix11.10.2023
ölçüsü306,38 Kb.
#127266
1   2   3   4   5   6   7   8   9   10
ProcedureSCBA

6
of 
10
Revision Date: 10/12/21 
COMPONENT 
LOOK FOR 

Loose inlet nipple; 

Dents or heat damage to housing; and 

Loose pressure port screws. 
Harness Frame 

Cylinder band and latch not working properly; 

Cylinder not secured in frame and band; 

Bent or broken frame; 

Webbing color change; excessive wear or fraying; cuts, nicks, nicks or broken 
stitching; 

Buckles damaged or corroded; and Loose Hardware. 
Air Cylinder & 
Valve 

Dents, gouges, blisters, or cuts; and external damage to cylinder valve; 

Smooth operation of valve hand wheel and ratchet collar; 

Loose screws securing rubber guard on cylinder valve

Condition of threads on valve outlet

Cylinder pressure gauge lens scratched; pointer deformed or stuck

Gauge reading incorrectly; and 

Hydrostatic test date within 3 years or 5 for carbon-fiber wrapped. 
Maintenance and Repair 
For SCBA units that fail inspection, the unit must be immediately taken out of service and red-tagged.
The deficiency must be noted in the inspection log and an authorized service facility with factory-trained 
technicians should be contacted for repair. Suggested authorized service facilities are the manufacturer 
or: 
Argus Group (Argus-HAZCO) 
46400 Continental Drive 
Chesterfield, MI 48047 
Phone: 1-800-873-0456 
Spears Fire and Safety Services, Inc. 
287 Jackson Plaza 
Ann Arbor, MI 48103 
Phone: 1-734-663-4133 
http://www.spearsfiresafety.com/
 
Refilling Air Cylinders 
Refilling of high-pressure cylinders (4,500 psi) is arranged through EHS-HMM (3-4568). EHS-HMM has 
purchased a breathing air system for refilling cylinders and it is located at the North Campus Transfer 
Facility. The unit is designed to deliver Grade E air that is purer than Grade D breathing air, which is the 
minimum allowed by law. HMM maintains a tag and logbook system for purification cartridge change-
out as well as having semi-annual testing and certification of the air by outside laboratory. 