Automatic computer control incubator xm-18 Operation Instruction


Temperature and humidity settings instance: This method is very simple, as long as you set up



Yüklə 138,36 Kb.
Pdf görüntüsü
səhifə2/7
tarix11.12.2023
ölçüsü138,36 Kb.
#144594
1   2   3   4   5   6   7
XM-18

Temperature and humidity settings instance: This method is very simple, as long as you set up
both points of temperature and humidity, others will generate automatically. For example, a
incubation control room needs that the temperature is 38 °C, humidity is 60% RH.
During normal working, press SET and lift your hand, a row of led will display on the lower
side of the controller.
If you need to change the temperature value, press
to adjust, till to display the temperature 38 °C you required. And then press [OK]
and raise your hand, the led will display on the lower side of the controller. If you
 need to change the humidity value, please press 
 to adjust un till the
required humidity 60% RH shows. And then press the key [OK], the controller will
automatically calculate andfill the parameters of temperature and humidity, and finally
return to normal working state.


Arbitrary temperature and humidity settings example
(which may change and automatically generate interval, but generally do not use it) During
normal operation, press the key [SET] and don't raise your hand, and then press the key 
[▲]
untill display 
 and then raise your hand, set up the following parameters:
Set up over-temperature alarm:
Led display as shown in right figure: 
"P1" is the over-temperature alarm value,
the alarm will be given if the temperature reaches this value. If any change is needed, please press
[▲▼] untill it displays the value you required. And press 
[OK]
and then raise your hand to save
data, and automatically move into the next parameter setting.
Set up over-temperature value:
Led display as shown in right figure:
 
"P2" is the over-temperature value, the
exhaust fan will be started up when the temperature reaches this value. If any change is needed,
please press [▲▼] untill it displays the value you required. And press 

Yüklə 138,36 Kb.