Appendix A  
|
  
Channel Specific Settings and Features 
Temperature 
(°C) 
Orion 
111.9mS/cm 
Conductivity 
Standard 
Cat. No. 
011005, 
01100510 
(mS/cm) 
Orion 
12.9mS/cm 
Conductivity 
Standard 
Cat. No. 
011006, 
01100610 
(mS/cm) 
Orion 
1413μS/cm 
Conductivity 
Standard 
Cat. No. 
011007, 
01100710 
(μS/cm) 
Orion 
147μS/cm 
Conductivity 
Standard 
Cat. No. 
01100910 
(μS/cm) 
Orion 
100μS/cm 
Conductivity 
Standard 
Cat. No. 
011008 
(μS/cm) 
26 
113.9 
13.10 
1441 
150 
102 
27 
115.9 
13.35 
1468 
153 
104 
28 
117.9 
13.59 
1496 
156 
106 
29 
120.0 
13.84 
1524 
159 
108 
30 
122.0 
14.09 
1552 
161 
110 
31 
124.1 
14.34 
1580 
164 
112 
32 
126.2 
14.59 
1608 
167 
114 
33 
128.3 
14.85 
1636 
170 
117 
34 
130.4 
15.10 
1665 
173 
119 
35 
132.5 
15.35 
1693 
176 
121 
36 
134.6 
15.61 
1722 
179 
123 
37 
136.7 
15.86 
1751 
182 
125 
38 
138.9 
16.12 
1780 
185 
127 
39 
141.0 
16.37 
1808 
188 
129 
40 
143.2 
16.63 
1837 
191 
131 
41 
145.4 
16.89 
1866 
194 
134 
42 
147.6 
17.15 
1896 
197 
136 
43 
149.8 
17.40 
1925 
200 
138 
44 
152.0 
17.66 
1954 
203 
140 
45 
154.2 
17.92 
1983 
206 
142 
46 
156.4 
18.18 
2013 
209 
145 
47 
158.7 
18.44 
2042 
212 
147 
48 
160.9 
18.70 
2071 
215 
149 
49 
163.2 
18.96 
2101 
219 
151 
50 
165.4 
19.22 
2130 
222 
154 
 
 
 
118  
|
  
Orion V
ERSA 
S
TAR
 Meter User Manual 
Thermo Scientific 


Appendix A  
|
  
Channel Specific Settings and Features 
Reference Temperature, Temperature Compensation and 
Temperature Coefficient 
V
ERSA 
S
TAR
 meters with a conductivity module offer several options for temperature 
compensated conductivity measurements. Temperature has a large effect on the conductivity 
value of a solution. The temperature compensation feature allows the meter to use the sample 
conductivity and temperature readings to calculate and display the conductivity that the sample 
would be expected to have at a selected reference temperature, such as 25 °C. To accurately 
use the temperature compensation feature, select the proper type of temperature compensation 
for the samples to be measured; set the required reference temperature as 5 °C, 10 °C, 15 °C, 
20 °C or 25 °C; and use a conductivity probe with built-in ATC temperature probe.   
The options for temperature compensation are: 
·
 
Linear – uses the temperature coefficient value to apply a constant percent correction 
factor to every degree change in temperature. A few common linear coefficient values are:  
Solution (25 °C to 50 °C) 
Temperature Coefficient (% / °C) 
Sugar Syrup 
5.64 
Ultra Pure Water 
4.55 
98 % Sulfuric Acid 
2.84 
Salt (NaCl) 
2.12 
Dilute Ammonia 
1.88 
5 % NaOH 
1.72 
10 % HCl 
1.32 
5 % Sulfuric Acid 
0.96 
 
·
 
nLFn (non-linear ultra pure non-degassed water) – applies a non-constant correction factor 
to pure water samples that have a varying response to changes in temperature. This mode 
is for temperature compensated readings of low conductivity waters that are in equilibrium 
with the carbon dioxide in air, such as pure waters reading near 1 μS/cm at 25 °C and 
natural waters having a composition comparable to natural ground, well or surface waters. 
·
 
nLFu (non-linear ultra pure degassed water) – applies a non-constant correction factor to 
pure water samples that have a varying response to changes in temperature. This mode is 
for temperature compensated readings of ultra pure water that contains no air and no 
carbon dioxide, such as ultra pure water (18 megohms resistance or higher) directly from 
the source without aeration. 
·
 
EP – no temperature correction is applied (temperature compensation turned off) and a 
warning is displayed if the measured conductivity value is over the EP requirement for pure 
water at the measured sample temperature. 
·
 
Off - no temperature correction is applied and the actual conductivity value is displayed at 
the measured sample temperature. 
Thermo Scientific 
Orion V
ERSA 
S
TAR
 Meter User Manual  
|
  
119
 


Appendix A  
|
  
Channel Specific Settings and Features 
Cell Type 
The V
ERSA 
S
TAR
 meter with conductivity module accepts 2-cell and 4-cell conductivity probes 
and allows the type of conductivity probe to be set as Standard (most conductivity probes) or 
USP (for the ultra pure water conductivity probe, Catalog Number 013016MD, when disabling 
temperature compensation). 
TDS Factor 
The V
ERSA 
S
TAR
 meter with conductivity module measures TDS as the total amount of 
dissolved inorganic material in a solution. The dissolved inorganic material carries a current that 
is measured by the conductivity probe. Since there is a direct relationship between conductivity 
and TDS, conductivity readings are used to estimate the presence of inorganic material using 
the TDS factor entered in the setup menu.   
The standard method of determining TDS involves evaporating a sample to dryness at 180 °C 
and weighing the residue. The TDS factor is calculated by taking the residue weight and 
dividing it by the sample conductivity. Subsequent conductivity readings are multiplied by the 
TDS factor to determine the TDS value of the sample. 
Salinity Type 
The V
ERSA 
S
TAR
 meter with conductivity module offers two salinity types: practical salinity and 
natural sea water. Practical salinity measurements are based on relating the sample 
measurement to the reading of a standard potassium chloride (KCl) solution at 15 °C. The 
V
ERSA 
S
TAR
 meter with conductivity module will automatically temperature compensate and 
report the expected practical salinity result as 
practical salinity units (psu)
 at 15 °C when using 
a conductivity probe with built-in temperature sensor. Natural sea water measurements use a 
historic convention known as UNESCO 1966 and the V
ERSA 
S
TAR
 meter with conductivity 
module will report the expected natural sea water result as 
parts per thousand (ppt)

 
 
120  
|
  
Orion V
ERSA 
S
TAR
 Meter User Manual 
Thermo Scientific 


Appendix A  
|
  
Channel Specific Settings and Features 
Dissolved Oxygen Settings 
Barometric Pressure Compensation 
The V
ERSA 
S
TAR
 meter with RDO/DO module has an internal barometer that can be used for 
automatic pressure compensated dissolved oxygen readings. Manual barometric pressure 
compensation can also be used if dissolved oxygen is measured with a submerged probe or in 
a pressurized vessel. The pressure must be entered as mm Hg. 
1 mm Hg = 0.03937 inch Hg = 1.3332 hPa (mBar) = 0.01934 PSI 
Salinity Correction 
Automatic salinity correction for dissolved oxygen readings reported as mg/L is available on the 
V
ERSA 
S
TAR
 meter with RDO/DO module when a conductivity module and conductivity probe 
are used simultaneously. The meter uses the conductivity value read by the conductivity probe 
to calculate the salinity correction factor and applies the factor to dissolved oxygen readings 
reported as mg/L. Manual salinity correction can be used for dissolved oxygen readings 
reported as mg/L on all V
ERSA 
S
TAR
 meters with RDO/DO module. The manual salinity 
correction factor must be entered as ppt (parts per thousand). 
Conductivity           
at 20 °C          
(mS/cm) 
Salinity 
Correction 
Value (ppt) 
 
Conductivity           
at 20 °C          
(mS/cm) 
Salinity 
Correction 
Value (ppt) 
 
Conductivity           
at 20 °C          
(mS/cm) 
Salinity 
Correction 
Value (ppt) 


 
20 
13 
 
35 
25 


 
21 
14 
 
36 
25 


 
22 
15 
 
37 
26 


 
23 
15 
 
38 
27 


 
24 
16 
 
39 
28 
10 

 
25 
17 
 
40 
29 
11 

 
26 
18 
 
42 
30 
12 

 
27 
18 
 
44 
32 
13 

 
28 
19 
 
46 
33 
14 

 
29 
20 
 
48 
35 
15 
10 
 
30 
21 
 
50 
37 
16 
10 
 
31 
22 
 
52 
38 
17 
11 
 
32 
22 
 
54 
40 
18 
12 
 
33 
23 
 
56 
42 
19 
13 
 
34 
24 
 
 
 
 
Calculated from the International Oceanographic Tables, Vol. 1, National Institute of 
Oceanography of Great Britain, Womley, Godaming, Surrey, England and Unesco, Paris 1971. 
 
 
Thermo Scientific 
Orion V
ERSA 
S
TAR
 Meter User Manual  
|
  
121
 


 
 


 
 
 
 
 
68X006501 0414 RevA 
thermoscientific.com/water 
© 2014 Thermo Fisher Scientific Inc. All rights reserved. RDO is a registered trademark of In-Situ Inc. Microsoft, Windows and Microsoft Vista are 
registered trademarks of Microsoft Corporation. All other trademarks are the property of Thermo Fisher Scientific Inc. & its subsidiaries. 
North America  
Toll Free: 1-800-225-1480 
Tel: 1-978-232-6000 
info.water@thermo.com 
 
Netherlands 
Tel: (31) 020-4936270 
info.water.uk@thermo.com
 
China 
Tel: (86) 21-68654588  
wai.asia@thermofisher.com
 
India 
Tel: (91) 22-4157-8800 
wai.asia@thermofisher.com
 
Singapore 
Tel: (65) 6778-6876 
wai.asia@thermofisher.com
 
Japan 
Tel: (81) 045-453-9175 
wai.asia@thermofisher.com
 
Australia 
Tel: (613) 9757-4300 
In Australia: (1300) 735-295 
InfoWaterAU@thermofisher
 
Water Analysis Instruments
 
 

Document Outline

  • 1
  • Chapter 1
  • Meter Introduction
    • Meter Overview
    • Packing List
    • Intended Use
  • 2
  • Chapter 2
  • Meter Basics
    • Using the Universal Power Adapter
    • Attaching the Electrode Stand
    • Meter Connections
    • Meter Keypad
      • Function Keys
      • /Numeric Keypad
    • Measurement Modules
      • Module Measurement Capabilities
      • Preconfigured Meter and Module Options
      • Inserting and Removing Modules
        • Module Insertion
      • Module Removal
      • Module Connections
    • Measurement Display Options
      • Single, Dual or Multiple Channel Displays
      • Measurement Display Examples
        • pH Mode Display
        • ISE Mode Display
        • pH/LogR Mode Display
        • Conductivity Mode Display
        • Dissolved Oxygen Mode Display
      • Additional Measurement Display Icons
      • pH Electrode Condition Icon
      • Customizing the Display
    • Meter and Module Maintenance
  • 3
  • Chapter 3
  • Meter Setup Menus
    • Main Setup Menu
    • Channel 1-4 Setup Menus
      • Method Menu
        • Load
        • Copy
        • Edit / Create
        • Delete
      • Temperature Menu
        • Temperature Unit
        • Temperature Input
        • Temperature Cal
          • ATC Probe Temperature Calibration
          • Manual Temperature Entry
    • Instrument Settings Setup Menu
    • Log View Menu
      • Data Log
      • Calibration Log
    • Diagnostics Menu
  • 4
  • Chapter 4
  • pH, pH/ISE and pH/LogR Measurement Modules
    • Connecting Electrodes to the Module
      • VSTAR-PH Versa Star pH Module
      • VSTAR-ISE Versa Star pH/ISE Module
      • VSTAR-LR Versa Star pH/LogR Module
    • Channel 1-4 Setup Menus
      • Mode Menus for pH, mV, Relative mV, ORP and ISE
        • /pH Mode Menu
        • mV, Relative mV and ORP Mode Menus
        • ISE Mode Menu (pH/ISE Module Only)
    • pH Calibration
      • pH Calibration Editing
        • Example pH Calibration Displays
    • Relative mV Calibration
    • ORP Calibration
    • ISE Calibration (pH/ISE Module Only)
      • ISE Calibration Editing
    • Temperature Calibration
      • ATC Probe Temperature Calibration
      • Manual Temperature Entry
      • LogR Temperature Calibration (pH/LogR Module Only)
        • LogR Temperature Calibration Recommendations
        • LogR Temperature Calibration Procedure
    • Incremental Techniques (pH/ISE Module Only)
      • Single Known Addition
      • Double Known Addition
      • Single Known Subtraction
      • Double Known Subtraction
      • Single Analate Addition
      • Single Analate Subtraction
  • 5
  • Chapter 5
  • Conductivity Measurement Module
    • Connecting Electrodes to the Module
      • VSTAR-CND Versa Star Conductivity Module
    • Channel 1-4 Setup Menus
      • Mode Menus for Conductivity, TDS, Salinity and Resistivity
        • Conductivity Mode Menu
        • TDS Mode Menu
        • Salinity Mode Menu
        • Resistivity Mode Menu
    • Conductivity Calibration
      • Automatic or Direct Conductivity Calibration
        • Conductivity Calibration Editing
        • Orion Conductivity Standard Values from 15  C to 30  C
      • Cell Constant Entry (Manual Conductivity Calibration)
    • Conductivity Verification Procedure
  • 6
  • Chapter 6
  • RDO/DO Measurement Module
    • Connecting Electrodes to the Module
      • VSTAR-RD Versa Star RDO/Dissolved Oxygen Module
    • Channel 1-4 Setup Menus
      • Mode Menus for Dissolved Oxygen
        • RDO and DO Mode Menu
      • RDO Electrode Information
    • Dissolved Oxygen Calibration
      • Water Saturated Air Calibration
      • Air Saturated Water Calibration
      • Manual (Winkler) Calibration
      • Set Zero Calibration
  • 7
  • Chapter 7
  • Meter Measurements
    • Measurement Overview
      • Example Measurement Mode and Channel Displays
    • Measurement Read Types
      • Auto-Read
      • Timed
      • Single-Shot
      • Continuous
        • Read Type Priority
    • Measurement Procedure
  • 8
  • Chapter 8
  • Data Transfer and Software Updates
    • Data Transfer Settings
      • Data Transfer Examples
    • Installing the Versa Star USB Driver Software
    • Meter Software Upgrade Procedure
    • Computer and Printer Compatibility
      • Computer Requirements
      • Printer Requirements
    • Versa Star Meter Remote Control Protocols
      • Remote Control Engine
      • Remote Control Commands
        • Meter Measurement Data from GETMEAS Command
        • Meter Calibration Data from GETCAL # Command
  • 9
  • Chapter 9
  • Customer Services
    • Troubleshooting Tips
      • Meter Self Test
    • WEEE Compliance
    • Declaration of Conformity
    • /Meter Specifications
    • Ordering Information
      • Versa Star Selectable Meter Components
      • Versa Star Preconfigured Meter Systems
      • Versa Star Meter Accessories, Electrodes and Solutions
  • A
  • Appendix A
  • Channel Specific Settings and Features
    • General Mode Settings
      • Sample ID
      • Stability
      • Averaging
      • Alarms
    • pH and ISE Mode Settings
      • Buffer Group and Automatic Buffer Recognition
        • Testing a pH Electrode for Automatic Buffer Recognition
      • Isopotential Value
        • Determining an Isopotential Value for an Ion Selective Electrode
      • Linear Regression
      • Blank Correction
      • Low Level Stability
    • LogR Temperature Technology
      • LogR Temperature Accuracy
      • Advanced pH Electrode Diagnostics using LogR Technology
        • Electrode Troubleshooting Using LogR Technology
        • Viewing Electrode Resistance
        • Out-Of-The-Box Electrode Check
        • Initial Electrode Check
        • Periodic Electrode Testing
        • Electrode Diagnostics Log
    • Conductivity, TDS, Salinity and Resistivity Mode Settings
      • Cell Constant (K) and Automatic Conductivity Calibration
      • Orion Conductivity Standard Values from 0  C to 50  C
      • Reference Temperature, Temperature Compensation and Temperature Coefficient
      • Cell Type
      • TDS Factor
      • Salinity Type
    • Dissolved Oxygen Settings
      • Barometric Pressure Compensation
      • Salinity Correction