27 |
P a g e
Figure: 1. 22. Dynamic characteristics of SCR
Hence , during the time t
3
to t
4
, the recombination of charges takes
place and at the instant t
4
, junction
J
2
completely recovers. This time is called
gate recovery time t
gr
.
From the figure the turn OFF time is the time interval between the t
4
and t
1
. Generally, this time
varies from 10 to 100 microseconds. This turn OFF time t
q
is applicable to the individual SCR.
The time required by the commutation circuit to apply the reverse voltage to commutate the SCR
is called the circuit turn OFF time (t
c
). For a safety margin or reliable commutation, this t
c
must
be
greater than the t
q
otherwise commutation failure occurs.
28 |
P a g e
The SCRs which have slow turn OFF time as in between 50 to 100 microseconds are called as
converter grade SCRs. These are used in phase controlled rectifiers, cyclo converters, AC voltage
regulators, etc.
The SCRs which have fast turn OFF time as in between 3 to 50 microseconds are inverter grade
SCRs. These are costlier compared to converter
grade and are used in choppers, force
commutated converters and inverters.