Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


Figure A.1d – Clearance gap between wall and screw



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə107/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   103   104   105   106   107   108   109   110   ...   138
Figure A.1d – Clearance gap between wall and screw
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
107
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


Annex B – (normative) – Motors not isolated from the supply mains and having basic insulation
not designed for the rated voltage of the tool
B.1 Scope
B.1.1 This annex applies to motors having a working voltage not exceeding 42 V, not isolated from the
supply mains, and having basic insulation not designed for the rated voltage of the tool.
All clauses of this standard apply to these motors, unless otherwise specified in this annex.
B.9 Protection against access to live parts
B.9.1 Metal parts of the motor are considered to be bare live parts.
B.12 Heating
B.12.3 The temperature rise of the body of the motor is determined instead of the temperature rise of the
windings.
B.12.5 The temperature rise of the body of the motor, where it is in contact with insulating material, shall
not exceed the values shown in Table 1 for the relevant insulating material.
B.15 Electric strength
B.15.3 The insulation between live parts of the motor and its other metal parts is not subjected to this test.
B.18 Abnormal operation
B.18.1 The test of 18.7 is not made.
Tools are also subjected to the test of B.18.101.
B.18.101 The tool is operated at rated voltage with each of the following defects:
– short circuit of the terminals of the motor, including any capacitor incorporated in the motor circuit;
– open circuit of the supply to the motor;
– open circuit of any shunt resistor during operation of the motor.
Only one defect is simulated at a time, the tests being made consecutively.