MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04
♦
UL 60745-1
111
Copyright Underwriters Laboratories Inc.
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---
Components
C shunt capacitor
S current range selector switch
D rectifier circuit diodes
M moving-coil meter
R
m
effective meter resistance
R
v
series resistance
R
1
fixed resistance
R
a
shunt resistor
Figure C.1 – Circuit for measuring leakage currents
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04
♦
UL 60745-1
112
Copyright Underwriters Laboratories Inc.
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---
Annex D – (normative) – Burning test
D.1 Burning test
The burning test is made in accordance with IEC 60707.
For the purpose of this standard, method FH of IEC 60707 (flame-horizontal specimen), is used.
For the evaluation of the test results, category FH-3 of IEC 60707 applies, the maximum burning rate
being 40 mm/min.
If more than one specimen does not withstand the test, the material is rejected.
If one specimen does not withstand the test, the test is repeated on another set of five specimens, all of
which shall then withstand the test.
Dostları ilə paylaş: |