Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


NOTE Examples for creepage distances are given in Annex A



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə26/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   22   23   24   25   26   27   28   29   ...   138
NOTE Examples for creepage distances are given in Annex A.
3.4.11 clearance : shortest distance between two conductive parts, or between a conductive part and
the outer surface of the enclosure, considered as though metal foil were pressed into contact with
accessible surfaces of insulating material, measured through air
NOTE Examples for clearance distances are given in Annex A.
3.4.12 normal duty conditions of insulating material : where there is virtually no deposition of conductive
material and a long period of electrical stress; or a light deposition of conductive material and a short
period of electrical stress
3.4.13 severe duty conditions of insulating material : where there is a light deposition of conductive
material and a long period of electrical stress; or a heavy deposition of conductive material and a short
period of electrical stress
3.4.14 extra-severe duty conditions of insulating material : where there is heavy deposition of
conductive material and a long period of electrical stress; or an extra heavy deposition of conductive
material and a short period of electrical stress
3.5.1 extra-low voltage : voltage supplied from a source within the tool and, which, when the tool is
supplied at rated voltage, does not exceed 50 V between conductors and between conductors and
earth
3.5.2 safety extra-low voltage : rated voltage not exceeding 42 V between conductors and between
conductors and earth, the no-load voltage not exceeding 50 V. When safety extra-low voltage is
obtained from the supply mains, it is to be through a safety isolating transformer or a convertor with
separate windings, the insulation of which complies with double or reinforced insulation requirements
3.5.3 safety isolating transformer : transformer, the input winding of which is electrically separated from
the output winding by an insulation at least equivalent to double insulation or reinforced insulation, and
which is intended to supply a distribution circuit, a tool or other equipment at safety extra-low voltage
3.6.1 hand-held tool (in this standard abbreviated to

tool

) : electric motor-operated or magnetically-
driven machine intended to do mechanical work, with or without provisions for mounting on a support,
and so designed that the motor and the machine form an assembly which can easily be brought to the
place of operation, and which is either held or supported by hand or suspended during operation