Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


 General conditions for the tests



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə29/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   25   26   27   28   29   30   31   32   ...   138
5 General conditions for the tests
5.1 Tests according to this standard are type tests.
5.2 Unless otherwise specified, the tests are made on a single tool, which shall withstand all the relevant
tests. However, any tool requiring modifications to perform the test or disassemble after the test shall be
performed on a separate sample.
The cumulative stress resulting from successive tests on electronic circuits is to be avoided. It may be
necessary to replace components or to use additional samples. The number of additional samples should
be kept to a minimum by an evaluation of the relevant electronic circuits.
5.3 Unless otherwise specified, the tests are carried out in the order of the clauses. If it is evident from
the construction of the tool that a particular test is not applicable, the test is not made.
5.4 The tests are carried out with the tool, or any movable part of it, placed in the most unfavourable
position that may occur in normal use.
5.5 Tools provided with controls or switching devices are tested with these controls or devices adjusted
to their most unfavourable settings, if the setting can be altered by the user. Electronic speed control
devices are set for the highest speed.
If the adjusting means of the control is accessible without the aid of a tool, this subclause applies whether
the setting can be altered by hand or with the aid of a tool. If the adjusting means is not accessible without
the aid of a tool, and if the setting is not intended to be altered by the user, this subclause does not apply.
Adequate sealing is regarded as preventing alteration of the setting by the user.
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
24
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


5.6 The tests are made in a draught-free location and, in general, at an ambient temperature of (20
±
5)°C.
If the temperature attained by any part is limited by a temperature sensitive device, or is influenced by the
temperature, the room temperature is, in case of doubt, maintained at (23
±
2)°C.
5.7.1 Tools for a.c. only are tested with a.c. at rated frequency, if marked, and those for a.c./d.c. are
tested at the more unfavourable supply.
Tools for a.c. which are not marked with rated frequency, or marked with a frequency range of 50 Hz to
60 Hz, are tested with either 50 Hz or 60 Hz, whichever is the more unfavourable.
5.7.2 Tools having more than one rated voltage are tested on the basis of the most unfavourable voltage.
When it is specified for tools marked with a rated voltage range that the supply voltage is equal to the
rated voltage multiplied by a factor, the supply voltage is equal to:
– the upper limit of the rated voltage range multiplied by this factor, if greater than 1;
– the lower limit of the rated voltage range multiplied by this factor, if smaller than 1.
When a factor is not specified, the supply voltage is the most unfavourable within the rated voltage range.
For tools having more than one rated voltage or rated voltage range, it may be necessary to make some
of the tests at the minimum, the mean, and the maximum values of the rated voltage, or the rated voltage
range, in order to establish the most unfavourable voltage.
5.7.3 For tools marked with a rated voltage range and rated input corresponding to the mean of the rated
voltage range, when it is specified that the power input is equal to rated input multiplied by a factor, the
input is equal to:
– the calculated input corresponding to the upper limit of the rated voltage range multiplied by
this factor, if greater than 1:
– the calculated input corresponding to the lower limit of the rated voltage range multiplied by
this factor, if smaller than 1.
When a factor is not specified, the input corresponds to the input at the most unfavourable rated voltage
within the range.
5.8 When alternative attachments are made available for the tool by its manufacturer, the tool is tested
with those attachments which give the most unfavourable results.
5.9 Unless otherwise specified, tools are tested with the appropriate flexible cord connected to the tool.
5.10 If class I tools have accessible metal parts which are not connected to an earthing terminal or
earthing contact, and are not separated from live parts by an intermediate metal part which is connected
to an earthing terminal or earthing contact, such parts are checked for compliance with the appropriate
requirements specified for class II construction.
If class I tools have accessible non-metallic parts, such parts are checked for compliance with the
appropriate requirements specified for class II construction, unless these parts are separated from live
parts by an intermediate metal part connected to an earthing terminal or earthing contact.