Summary of Topics This is the Third edition of ansi/ul 60745-1, the Standard for Safety for Hand-Held Motor- operated Electric Tools – Safety – Part 1: General Requirements and is based on iec 60745-1


NOTE Hand-held tools may be provided with a flexible shaft, the motor being either fixed or portable



Yüklə 4,83 Kb.
Pdf görüntüsü
səhifə27/138
tarix22.03.2024
ölçüsü4,83 Kb.
#181520
1   ...   23   24   25   26   27   28   29   30   ...   138
NOTE Hand-held tools may be provided with a flexible shaft, the motor being either fixed or portable.
3.6.2 exchange type tool : tool which is intended not to be repaired at all, or to be repaired by the
manufacturer’s service organization only
3.7.1 non-detachable part : part which can only be removed or opened with the aid of a tool, or a part
which fulfils the test of 21.22
3.7.2 detachable part : part which can be removed or opened without the aid of a tool, or a part which
is removed in accordance with the instruction for use, except user maintenance items, even if removal
requires the use of a tool
MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
22
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


3.8.1 thermostat : temperature-sensing device, the operating temperature of which may be either fixed
or adjustable; and which, during normal operation, keeps the temperature of the controlled part between
certain limits by automatically opening and closing a circuit
3.8.2 temperature limiter : temperature-sensing device, the operating temperature of which may be
either fixed or adjustable, and which, during normal operation, operates by opening or closing a circuit
when the temperature of the controlled part reaches a predetermined value. It does not make the
reverse operation during the normal duty cycle of the tool
3.8.3 thermal cut-out : device which, during abnormal operation, limits the temperature of the controlled
part by automatically opening the circuit, or by reducing the current, and which is so constructed that its
setting cannot be altered by the user
3.8.4 self-resetting thermal cut-out : thermal cut-out which automatically restores the current after the
relevant part of the tool has cooled down to a given value
3.8.5 non-self-resetting thermal cut-out : thermal cut-out which requires a manual operation for
resetting, or replacement of a part, in order to restore the current
3.8.6 protective device : device the operation of which prevents a hazardous situation under abnormal
operation conditions
3.8.7 thermal link : thermal cut-out which operates only once, and then requires partial or complete
replacement
3.9.1 all-pole disconnection disconnection of all supply conductors except the protective earthing
(grounding) conductor by a single initiating action
3.9.2 accessible part : part which can be touched by means of the standard test finger in Figure 1,
including, for accessible metal parts, any metal part connected to it
3.9.3 live part : any conductor or conductive part intended to be energized in normal use, including a
neutral conductor but, by convention, not a PEN conductor
3.10.1 electronic component : part in which conduction is achieved principally by electrons moving
through a vacuum, gas or semiconductor, with the exclusion of neon indicators
3.10.2 electronic circuit : circuit incorporating at least one electronic component
3.10.3 protective impedance : impedance connected between live parts and accessible conductive