MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
69
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


- for non-self-resetting thermal cut-out which is manually reset, 10 cycles of operation.
Automatic controls which comply with the requirements of IEC 60730-1, and which are used in
accordance with their marking, are considered to meet the requirements of this standard (the term

marking

includes documentation and declaration as specified in clause 7 of IEC 60730-1).
The tests of clause 17 of IEC 60730-1 are not carried out on automatic controls which operate during
clause 12, if the tool meets the requirements of this standard when they are short-circuited.
A specific exception with regard to the testing of thermostats and temperature limiters is made in note 2)
of Table 1 of Clause 12.
23.1.7 The testing of components which have to comply with other standards is, in general, carried out
separately, according to the relevant standard as follows.
If the component is marked and used in accordance with its marking, it is tested in accordance with its
marking, the number of samples being that required by the relevant standard.
In particular, components not mentioned in Table 1 of clause 12 are tested as a part of that tool.
23.1.8 Where no IEC standard exists for the relevant component, or where the component is not marked,
or is not used in accordance with its marking, the component is tested under the conditions occurring in
the tool, the number of samples being, in general, that required by a similar specification.
23.1.9 For capacitors connected in series with a motor winding, it is verified that, when the tool is
operated at a voltage equal to 1,1 times rated voltage and under minimum load, the voltage across the
capacitor does not exceed 1,1 times the rated voltage of the capacitor.
23.1.10 Mains switches shall have adequate breaking capacity, and shall be switches for 50 000 cycles
of operation.
Compliance is checked by inspection and by the following test.
Mains switches are tested together with the tool at rated voltage or at the upper limit of the rated voltage
range of the tool.
The motor is then stalled, and the switch is operated 50 times, each

on

period being not more than 0,5
s, and each

off

period being not less than 10 s.
If, in normal use, an electronic control device switches off the current before opening the main contacts,
the number of operations is reduced to five, with the electronic control device short-circuited.
After the test, the switch shall have no electrical or mechanical failure.
Mains switches marked with individual ratings are also tested in accordance with IEC 61058-1.