MARCH 26, 2004
CAN/CSA-C22.2 NO. 60745-1-04

UL 60745-1
70
Copyright Underwriters Laboratories Inc. 
Provided by IHS under license with UL
Licensee=CSA Group/5934117001, User=YUEN, Ruby
Not for Resale, 12/21/2004 21:51:39 MST
No reproduction or networking permitted without license from IHS
--````,```,`,`,``,`,,,,,,,``,,,-`-`,,`,,`,`,,`---


23.1.11 Switches, which have not been separately tested and found to comply with IEC 61058-1 under
the conditions occurring in the tool, shall comply with Annex I.
The test of 17.2.4.4 of IEC 61058-1 is carried out for 50 000 cycles of operation.
Switches intended for operation under no load, and which can be operated only with the aid of a tool, are
subjected to the tests of clause 17 of IEC 61058-1. This applies also to such switches operated by hand
which are interlocked so that they cannot be operated under load, but switches without that interlock are
subjected to the test of 17.2.4.4 for 100 cycles of operation.
The tests of 17.2.4.4 of IEC 61058-1 are not carried out on a switch if the tool meets the requirements of
this standard when the switch is short-circuited.
23.2 Tools shall not be fitted with
– switches or automatic controls in flexible cords;
– devices which cause the protection device in the fixed wiring to operate in the event of a fault
in the tool;
– thermal cut-outs which can be reset by a soldering operation.
Compliance is checked by inspection.
23.3 Overload protection devices shall be of the non-self-resetting type.
Compliance is checked by inspection.
23.4 Plugs and socket-outlets used as terminal devices for heating elements, and plugs and
socket-outlets for extra-low voltage circuits, shall not be interchangeable with plugs and socket-outlets
listed in IEC 60884, and with connectors and tool inlets complying with the standard sheets of IEC 60320.
Compliance is checked by inspection
23.5 Motors connected to the supply mains, and having basic insulation which is inadequate for the rated
voltage of the tool, shall comply with the requirements of Annex B.
Compliance is checked by the tests of Annex B.