24.1DV D2
Modification: Add the following sentence:
A supply cord shall be less than 0,5 m or greater than 1,8 m long.
24.2 Supply cords shall be assembled to the tool by one of the following methods:
– type X attachment;
– type Y attachment;
– type Z attachment, only for exchange-type tools, as allowed in part 2.
Supply cords with type X and type Y attachment may be either ordinary flexible cords or special cords and
only available from the manufacturer or his service agent. A special cord may also include a part of the
tool.
Compliance is checked by inspection and, if necessary, by manual test.
24.3 Plugs shall not be fitted with more than one flexible cord.
Compliance is checked by inspection.
24.4 Supply cords shall be not lighter than:
– ordinary tough rubber sheathed flexible cord (code designation 60245 IEC 53);
– ordinary polyvinyl chloride sheathed flexible cord (code designation 60227 IEC 53).
Polyvinyl chloride insulated flexible cords shall not be used for tools having external metal parts, the
temperature rise of which exceeds 75 K during the test of clause 12.
Compliance is checked by inspection and measurement.
If provided with a plug, power supply cords of single-phase tools having a rated current not exceeding 16
A shall be provided with a plug complying with IEC 60884 or IEC 60309.
If plugs complying with IEC 60309 are fitted, the standard sheets to be applied are as follows:
– class I tools
Sheet 2 – I
– class II tool
Sheet 2
– class III tools
Sheet 2 – I
The body of the plug shall be of, or covered with, rubber, polyvinyl chloride or material, having no less
mechanical strength.
Power supply cords of single-phase tools, having a rated current exceeding 16 A but not exceeding 63 A,
and of multi-phase tools having a rated current not exceeding 63 A, shall be provided with a plug
complying with IEC 60309, the standard sheets to be applied being as follows:
– class I tools
Sheet 2 – III according to current
– class II tools
Sheet 2