70
XFlow
-
-
-
x: Fully supported
-: Not supported
E: Carried out as emulation (performance loss possible, determinism is limited in the PLC cycle, driver
selection at a BSOD)
1: The driver specific function blocks do not work under straton RTK.
2: Hilscher DLLs must be available on the target platform.
The straton I/O drivers support the Hot-Restart or Online Change in different ways:
Anybus Configuration
x
x
x
1
ApplicomIO Configuration
x
x
x
1
AS-interface
x
x
x
1
BECKHOFF CX1000
x
x
-
Brodersen IOTOOLS
x
x
x
1
Hilscher CIF Profibus
x
x
-
Hilscher SYCON Configuration
x
x
x
1
Hischer SYCON Configuration
[universal]
x
x
x
1
Hilscher SYCON.net Configuration
x
x
x
1
71
IEC 61850 Client
x
x
-
Interbus-S
x
x
-
MODBUS Master Protocol
x
x
x
1
MODBUS Slave Protocol
x
x
x
1
PROFINET IO
x
x
-
SoftNet ProfibusDP
x
x
x
1
straton to zenon Runtime
connection
x
x
-
2
ThinkIO/IO System 758
x
x
-
Weihenstephan Standard - Client
x
x
x
1
Win32 Shared memory
x
x
x
1
x: Functionality available
-: Functionality not available
1: Online Change including the change of the bus driver configuration is always followed by the
reinitialization of the I/O driver. Because of the reinitialization I/Os can fail for a short period!
2: No need for change in the bus driver configuration.
72
The straton Runtime Manager administrates all straton Runtime projects, which are stand alone or must
be started manually, on your computer. It does not matter whether there is a zenon Runtime installed on
the computer.
If you created your straton project in zenon and you set the zenon property of the straton
project RT start type to
start manually
, the straton Runtime Manager is the ideal tool for
organizing the parameters for the manual start.
If you want to start your straton Runtime project during the booting of the Windows operating
system, you can set this with one mouse click in the straton Runtime Manager.
If you want to reorganize your straton project, you can do this with the straton Runtime
Manager.
If you want to run the straton Runtime autarchically (without the zenon Runtime), it is best to
call up the straton Runtime instance using the straton Runtime Manager.
Configurations: There you can administrate the straton Runtime projects
Languages: There you can switch between languages online
Settings: Enter the path of the straton Runtime
?: Open the help
Exit: Exits the program -
Do not forget to save the settings before you exit the straton
Runtime Manager!
73
Place the mouse cursor over an element in the straton Runtime Manager in order to see the
corresponding help text in the property help.
In addition all elements of the straton Runtime Managers are described here:
6.3.1
Configuration list
This list contains all available straton Runtime configurations.
Click on an entry in the list in order to display its parameter settings.
After that click on Edit in order to change the parameters.
Click on Save in order to save the changes.
6.3.2
straton project folder
The selected path of the straton Runtime project (storage location of the PLC code) is entered there
automatically. You can change this entry manually by left-clicking the folder symbol.
Info
Before you are able to edit any setting which you have already saved, you must first select
the concerning configuration in the list. After that click on button Edit. In order to save
the changes, click on button Save.
6.3.3
Name of the configuration
The name of the last path of the straton Runtime files is entered automatically if a new configuration is
created. You can changes this name freely.
74
Info
Before you are able to edit any setting which you have already saved, you must first select
the concerning configuration in the list. After that click on button Edit. In order to save
the changes, click on button Save.
6.3.4
Port (Main)
Enter the main port for the straton Runtime instance. This port defines the connection of the straton
Workbench and a zenon drivers. Per default this port is set to 1200.
Info
Before you are able to edit any setting which you have already saved, you must first select
the concerning configuration in the list. After that click on button Edit. In order to save
the changes, click on button Save.
6.3.5
Port (Binding)
Enter the binding port for the straton Runtime instance. The binding port defines the connection for
spontaneous TCP/IP communication to other straton Runtimes. Per default this port is set to 7800
higher than the main port.
Info
Before you are able to edit any setting which you have already saved, you must first select
the concerning configuration in the list. After that click on button Edit. In order to save
the changes, click on button Save.
75
6.3.6
Startup
Define the startup behavior of the straton Runtime instance.
Cold start - The straton Runtime starts with initialized variables.
Cold start (load RETAIN variables) - The straton Runtime starts initialized with remanent
markers.
Hot restart - The straton Runtime starts with the variable values from the time the Runtime was
stopped.
Info
Before you are able to edit any setting which you have already saved, you must first select
the concerning configuration in the list. After that click on button Edit. In order to save
the changes, click on button Save.
6.3.7
Start in step mode
In order to start the straton Runtime in step mode, activate this checkbox.
Info
Before you are able to edit any setting which you have already saved, you must first select
the concerning configuration in the list. After that click on button Edit. In order to save
the changes, click on button Save.
6.3.8
Windows real time priority
In order for the straton Runtime instance to run in the Windows real time priority, activate this check
box.
76
Info
We recommend to always have the real time priority activated. First and foremost
deactivating the real time priority is used for testing purposes (e.g. if there may be infinite
loops).
Info
Before you are able to edit any setting which you have already saved, you must first select
the concerning configuration in the list. After that click on button Edit. In order to save
the changes, click on button Save.
6.3.9
Hard real time
If you activate this checkbox, the straton real time PLC (straton RTK) is called up when the
configuration is started. As the straton real time PLC may only run once on the computer, it is validated
that this checkbox is only activated for one configuration.
Info
Before you are able to edit any setting which you have already saved, you must first select
the concerning configuration in the list. After that click on button Edit. In order to save
the changes, click on button Save.
6.3.10
Report output
Activate this checkbox in order to activate the writing of messages of the Runtime in a log file.
77
Info
Writing a log file will influence the performance.
Info
The log file is named "straton RTLOG.txt" and is saved in the straton Runtime project
folder.
Info
Before you are able to edit any setting which you have already saved, you must first select
the concerning configuration in the list. After that click on button Edit. In order to save
the changes, click on button Save.
6.3.11
Auto start
In order to start a straton Runtime instance directly with the booting of the Windows operating system,
activate this checkbox.
Info
Before you are able to edit any setting which you have already saved, you must first select
the concerning configuration in the list. After that click on button Edit. In order to save
the changes, click on button Save.
78
6.3.12
Button "New"
If you want to create a configuration, click on button New. After that a dialog opens in which you can
select the folder in which you want to save the
Confirm your selection with OK. You can change the name of the configuration. In order to save the
configuration and the name of the configuration, click on Save.
6.3.13
Button "Edit"
Before you can change the parameters of a configuration, you must click on button Edit after you
have selected an entry from the configuration list. In order to save the changes, you must click on
Save.
6.3.14
Button "Save"
Click on button Save in order to save all changes.
6.3.15
Button "Delete"
In order to delete a configuration, select the entry from the configuration list and click on button
Delete.
6.3.16
Button "Start"
In order to start the straton Runtime with the respective configuration, select a configuration from the
list and click on button Start. The straton Runtime starts immediately.
79
Info
If the folder of the configuration does not contain any straton Runtime files (PLC code), the
straton Runtime starts in mode No program.
6.3.17
straton Runtime (settings)
Enter the folder of the straton Runtime (folder of stratonRT.exe). In order to browse through your hard
disk, left-click the folder symbol.
6.3.18
Language selection (languages)
Select the desired language by clicking on the respective flag.
6.3.19
Show splash screen (setting)
If you activate this check box, the splash screen of the straton Runtime Manager is displayed at the
start.
Document Outline - Welcome to COPA-DATA help
- straton
- Basics straton Workbench (IEC 61131-3)
- General information about this help chapter
- straton General
- straton toolbar and context menu detail view
- First steps with straton in zenon
- Create a straton project in a zenon project
- Edit a straton project
- Design of the Workbench
- Variable handling
- Create O and M variables in straton
- Create O and M variables in zenon
- Using zenon variables in straton
- Variable names
- Arrays
- Data structures
- Distributed engineering (multiuser)
- Reusing projects
- straton Workbench
- straton Runtime (Soft PLC)
- User interface
- Slider Allowed maximum
- Settings
- General
- Redundancy
- Advanced users
- Messages
- Licensing
- Start the straton Runtime
- straton Runtime cycle
- Close the straton Runtime
- Remote systems
- straton Runtime with Real Time Kernel (RTK)
- Restrictions and requirements of the straton RTK
- straton RTK configuration
- Start RTK configuration
- RTK basis information
- RTK basic settings
- RTK Taskmanager
- RTK hardware configuration
- RTK Logs
- Close RTK configuration
- Blue Screen Handling
- Error codes when starting stratonRTK
- Redundancy straton and zenon
- Requirements
- Configure redundancy
- OEM spezifikation
- straton I/O driver support
- straton I/O driver: Hot-Restart/Online Change
- straton Runtime Manager
- Why should you use the straton Runtime Manager?
- Main menu
- Properties help
- Configuration list
- straton project folder
- Name of the configuration
- Port (Main)
- Port (Binding)
- Startup
- Start in step mode
- Windows real time priority
- Hard real time
- Report output
- Auto start
- Button "New"
- Button "Edit"
- Button "Save"
- Button "Delete"
- Button "Start"
- straton Runtime (settings)
- Language selection (languages)
- Show splash screen (setting)
Dostları ilə paylaş: |