Chapter 7  
|
  
Meter Measurements 
Measurement Procedure 
As needed, customize the information shown in the measurement mode using the
 Instrument 
Settings
 setup menu. If two or more modules are connected to the meter, while in the 
measurement mode press the channel key until the desired combination of meter channels are 
shown. Select the read type for all meter channels shown in the measurement mode.  
Prepare the electrodes according to the instructions in the electrode user manuals. Connect the 
electrodes to the module inputs on the displayed channels. Make sure the electrodes are 
properly calibrated and working correctly.  
1.
 
Rinse the electrodes with distilled water or appropriate solution, blot dry with a lint-free 
tissue and place into the sample. 
2.
 
Start the measurement and wait for the reading to stabilize or reach the predefined time. 
a.
 
Auto-Read: Press the measure (esc) key to start the measurement. If using a stirrer 
probe, the stirrer probe will start stirring when the measure (esc) key is pressed and 
stop stirring when the measurement stabilizes. 
b.
 
Timed: Measurements will start immediately when in the measurement mode. If using a 
stirrer probe, press the stirrer key to start and stop stirring. 
c.
 
Single-Shot: Press the measure (esc) key to start the measurement. If using a stirrer 
probe, the stirrer probe will start stirring when the measure (esc) key is pressed and 
stop stirring when the predefined wait time has elapsed. 
d.
 
Continuous: Measurements will start immediately when in the measurement mode. If 
using a stirrer probe, press the stirrer key to start and stop stirring. 
3.
 
Once the measurement is stable or reaches the set time, record all applicable parameters. 
a.
 
Auto-Read: Once the measurement is stable, it will be locked and held on the display 
and the AR icon will remain solid. If the data log function is enabled, the measurement 
will be exported to the data log. 
b.
 
Timed: Measurements will be recorded at the predefined time interval. If the data log 
function is enabled, the < icon will be shown when each time interval has elapsed and 
the measurement is exported to the data log. 
c.
 
Single-Shot: Once the predefined wait time has elapsed, the measurement will be 
locked and held on the display. If the data log function is enabled, the measurement will 
be exported to the data log.  
d.
 
Continuous: The flashing Stabilizing icon will update to the solid Ready icon when the 
measurement is stable. If the data log function is enabled, press the log/print key to 
export the measurement to the data log.  
4.
 
Remove the electrodes from the sample, rinse with distilled water or appropriate solution, 
blot dry with a lint-free tissue and place into the next sample. 
5.
 
Repeat steps 2 through 4 for all samples. When all samples have been measured, store the 
electrodes according to the instructions in the electrode user manuals. 
74  
|
  
Orion V
ERSA 
S
TAR
 Meter User Manual 
Thermo Scientific 


Chapter 7  
|
  
Meter Measurements 
Measurement Tip – Using the Electrode Holder 
It is recommended that electrodes be placed in the meter-attached electrode stand for easy 
movement in and out of beakers during calibration, sample measurement and storage. 
The included electrode stand can be attached to either side of the meter. The recommended 
electrode positions for the electrode holder portion of the stand are shown below. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
15 mm holder for conductivity and 
dissolved oxygen probes 
Stirrer probe holder 
12 mm flexible holder for pH, ORP 
and ion selective electrodes 
Optional RDO optical DO probe holder 
12 mm holder with optional 
ATC probe insert 
Holder with 20° angle for ion 
selective electrodes 
Thermo Scientific 
Orion V
ERSA 
S
TAR
 Meter User Manual  
|
  
75
 


 

Data Transfer and Software Updates 
Data Transfer Settings 
Review the following sections of this user manual for detailed information on the data storage 
and transfer settings available with V
ERSA 
S
TAR
 meters. 
User Manual Section 
Topic for Review 
Meter Connections 
Meter inputs used to connect a computer or printer  
Instrument Settings 
Meter communication, data log and printing settings 
Log View 
Viewing and exporting the data log and calibration log from the meter to 
an external device 
Measurement Read Types 
How the meter takes a measurement and when the measurement is sent 
to the data log and external device 
 
If measurements will be saved to the data log and then transferred to a computer or printer, 
make sure the data log is enabled in the setup menu, the meter communication settings match 
the computer or printer settings and the meter and computer or printer are properly interfaced. 
The Orion Star Com communication software is compatible with V
ERSA 
S
TAR
 meters and a free 
download is available at 
www.thermoscientific.com/OrionMeters
. The Star Com software 
facilitates the transfer of calibration and measurement data from the meter to a computer and 
then allows data to be exported to an Excel (.xls) or Comma-Separated Values (.csv) file. 
Transferred data can also be printed from the computer. V
ERSA 
S
TAR
 meters must have 
software revision 2.73 or higher to use the Star Com software. The V
ERSA 
S
TAR
 USB driver 
software must be installed on the computer if the USB port will be used to connect the meter 
with a computer. 
C H A P T E R   8  
76  
|
  
Orion V
ERSA 
S
TAR
 Meter User Manual 
Thermo Scientific 