Chapter 2  
|
  
Meter Basics 
Meter Keypad 
The V
ERSA 
S
TAR
 meter keypad includes menu-specific function keys that update on the display 
for fast and efficient meter operation, a numeric keypad to facilitate data entry and shortcut keys 
for easy navigation to the measurement, setup, calibration, data log and calibration log menus.   
 
 
Key Icon and Name 
Function 
 
power 
Press the power key to enter the standby meter mode with screen saver. Press 
the power key a second time to enter the active meter mode. 
 
f1, f2, f3 
Press the f1f2 and f3 function keys to perform the action shown above each key 
on the display. 
 
channel 
Press the channel key when two or more modules are connected to the meter to 
change the measurement display to show each channel individually or a 
combination of two or more channels simultaneously.  
 
measure (esc) 
Press the measure (esc) key in the AUTO-READ measurement mode to start a 
new measurement. Press to escape to the measurement mode from other modes 
and menus. Press to enter a value of one (1) when using the numeric. 
 
up arrow (▲) 
Press the up arrow (▲) key to scroll up through a list of items.  
Press to enter a value of two (2) when using the numeric keypad. 
 
setup 
Press the setup key to enter the setup menu from the measurement mode.  
Press to enter a value of three (3) when using the numeric keypad. 
 
cal 
Press the cal key to enter the calibration menu from the measurement mode.  
Press to enter a decimal point (.) when using the numeric keypad. 
 
left arrow (◄) 
Press the left arrow (◄) key to scroll left through a list of items.  
Press to enter a value of four (4) when using the numeric keypad. 
Thermo Scientific 
Orion V
ERSA 
S
TAR
 Meter User Manual  
|
  
11
 


Chapter 2  
|
  
Meter Basics 
Key Icon and Name 
Function 
 
enter 
Press the enter key to select an option.  
Press to enter a value of five (5) when using the numeric keypad.  
 
right arrow (►) 
Press the right arrow (►) key to scroll right through a list of items.  
Press to enter a value of six (6) when using the numeric keypad. 
 
stirrer 
Press the stirrer key to turn the stirrer probe on and off in the continuous or 
timed measurement mode and the calibration edit mode.  
Press to make a value positive or negative (+/-) when using the numeric keypad. 
 
mode 
Press the mode key to change the measurement mode of a channel. 
Press to enter a value of seven (7) when using the numeric keypad. 
 
down arrow (▼) 
Press the down arrow (▼) key to scroll down through a list of items.  
Press to enter a value of eight (8) when using the numeric keypad. 
 
log view 
Press the log view key to access the data log and calibration log from the 
measurement mode.  
Press to enter a value of nine (9) when using the numeric keypad. 
 
log/print 
Press the log/print key to manually log, print, or log and print a measurement, 
depending on the selected measurement mode and data output settings.  
Press to enter a value of zero (0) when using the numeric keypad. 
 
Function Keys 
The following image shows the f1f2 and f3 keys with their corresponding actions above each 
function key on the meter display. Pressing the f1 (Cal) key will prompt the meter to enter the 
calibration mode. Pressing the f2 (Sample ID) key will prompt the meter to enter the sample ID 
setup mode. Pressing the f3 (Setup) key will prompt the meter to enter the main setup menu. 
 
 
Numeric Keypad 
The following drawing shows the keys that are active when 
entering a value using the numeric keypad. The decimal (.
key and plus/minus (+/-) key are active so fractional values 
and positive or negative values can be entered as needed.  
12  
|
  
Orion V
ERSA 
S
TAR
 Meter User Manual 
Thermo Scientific 


Chapter 2  
|
  
Meter Basics 
Measurement Modules 
The V
ERSA 
S
TAR
 meter has four channels that can be configured in any combination using 
V
ERSA 
S
TAR
 measurement modules. The type of module connected to the channel will define 
the measurement capability of that channel. Measurement modules are automatically 
recognized by the meter and can be added or removed from a channel at any time. Five V
ERSA 
S
TAR
 modules are available for pH, pH/ISE, pH/LogR, conductivity and dissolved oxygen.  
Module Measurement Capabilities 
The table below shows the module part number, module label shown on the top tab and 
measurement modes. All measurements include temperature. 
Module Catalog # 
VSTAR-PH  VSTAR-ISE  VSTAR-LR  VSTAR-CND 
VSTAR-RD 
Label 
pH 
pH/ISE 
pH/LogR 
Cond 
RDO/DO 
Measurement Modes 
pH 
pH 
pH 
Conductivity 
% Saturation 
mV 
mV 
mV 
TDS 
mg/L 
RmV 
RmV 
RmV 
Salinity 
 
ORP 
ORP 
ORP 
Resistivity 
 
 
ISE 
 
 
 
Temperature Modes 
Automatic 
Automatic 
Automatic 
Automatic 
Automatic 
Manual 
Manual 
Manual 
Manual 
 
 
 
LogR 
 
 
 
Preconfigured Meter and Module Options 
V
ERSA 
S
TAR
 meters can be purchased without modules or preconfigured with up to four 
modules included. Preconfigured V
ERSA 
S
TAR
 meters will have the modules already connected 
with the channels. Any open channels will be covered with blank modules.  
1.
 
VSTAR-PH (pH), VSTAR-ISE (pH/ISE), VSTAR-CND (Conductivity) and VSTAR-RD 
(RDO/Dissolved Oxygen) measurement modules – each connects with one channel.  
2.
 
VSTAR-LR (pH/LogR) measurement module connects with two channels. 
3.
 
Unused channels are covered with blank modules. 
 
 
 
Meter with pH/ISE module, conductivity module, 
RDO/DO module and blank module (right to left) 
  Meter with pH module, pH/LogR module and 
blank module (right to left) 
Thermo Scientific 
Orion V
ERSA 
S
TAR
 Meter User Manual  
|
  