Chapter
2
|
Meter Basics
View Format
Displayed Information (Customizable & Measurement Dependent)
Example Two
Channel Display
Three Channels
–
Channels 1, 2 & 3
–
Channels 1, 2 & 4
–
Channels 1, 3 & 4
–
Channels 2, 3 & 4
–
Channel ID
–
Print, Log, RS232/USB Icons
–
Date
and Time
–
Channel Number
–
Measurement Mode
–
Method Number
–
Read Type (AR, TM, SS) Icons
–
Stabilizing/Ready Indicator
–
Main Measurement with Units
–
Secondary Measurement with Units
–
Temperature with Units and Source
Example Three
Channel Display
Four Channels
–
Channels 1, 2, 3 & 4
–
Channel ID
–
Print, Log, RS232/USB Icons
–
Date and Time
–
Channel Number
–
Measurement Mode
–
Method Number
–
Read Type (AR, TM, SS) Icons
–
Stabilizing/Ready Indicator
–
Main Measurement with Units
–
Secondary Measurement with Units
–
Temperature with Units and Source
Example Four
Channel Display
Thermo
Scientific
Orion V
ERSA
S
TAR
Meter User Manual
|
17
Chapter
2
|
Meter Basics
Measurement Display Examples
pH Mode Display
mV Mode Display
RmV Mode Display ORP Mode Display
ISE Mode Display
pH/LogR Mode Display
Ion selective electrode (ISE) type
Calibration information with
calibration points, date and time of
most recent active
calibration
Main measurement mode
Main
measurement value
Channel ID for
measurement
modules connected
to meter
Channel number
Date
and time
Method
Temperature measurement and source
Main measurement units
mV corresponding
to main measurement
ISE condition icon and slope value of
most recent active calibration
Date and time
Method
Temperature measurement and source
Main measurement units
mV corresponding to main measurement
pH electrode condition icon and slope
value of most recent active calibration
Channel ID for measurement
modules connected to meter
Channel number
Main measurement mode
Main measurement value
Calibration information with
calibration points, date and time of
most recent active calibration
pH bulb resistance, appears with LogR
temperature compensation
Date and time
Method
Main measurement units
mV corresponding to main measurement
Main measurement mode
Channel number
Channel ID for measurement
modules connected to meter
Main measurement value
Temperature measurement
and source
18
|
Orion V
ERSA
S
TAR
Meter User Manual
Thermo Scientific
Chapter
2
|
Meter Basics
Conductivity Mode Display
Dissolved Oxygen Mode Display
Additional Measurement Display Icons
Icon
Name
Description
Printer Icon
Signals when a measurement is sent to a printer or computer
(measurement read type dependent). Printing option must be set to On
in the Instrument Settings setup menu.
Data Log Icon
Signals when a measurement is recorded in the data log
(measurement read type dependent). Data log option must be set to
On in the Instrument Settings setup menu.
Alarm Icon
Shown when a meter alarm is triggered. The
corresponding alarm
identification will also flash on the display as
High Limit Alarm
,
Low
Limit Alarm
,
Cal Due Alarm
or
Set Point Alarm
. Alarm must be enabled
in the channel-specific setup menu.
Channel ID for measurement
modules connected to meter
Channel number
Date and time
Method
Main measurement units
Calibration information with
calibration points, date and time of
most recent active calibration
Main measurement value
Main measurement mode
RDO optical cap information
(changes from green to red with
30 days or less of cap life)
Calibration information with
calibration type, date and time of
most recent active calibration
Main measurement value
Date and time
Barometric pressure
Channel ID for measurement
modules connected to meter
Channel number
Main measurement mode
Salinity value
Method
Temperature measurement and source
Temperature compensation setting
Temperature measurement and source
Main measurement units
Thermo Scientific
Orion V
ERSA
S
TAR
Meter User Manual
|
19