IEC60904-9-2020

5.4.1.3 
Determination of LTI 
LTI relates to the time for acquiring the I-V characteristics in the following measurement 
concepts: 
a) For a three channel I-V measurement (irradiance, current, voltage) with a pulsed or 
steady-state solar simulator, the LTI value is related to the time for acquiring the I-V 
characteristic. 
b) For a two channel I-V measurement (voltage, current) with a pulsed or steady-state solar 
simulator, irradiance shall be measured before and after I-V measurement. The LTI value 
shall be calculated from these two irradiance values. The LTI value may depend on the I-V 
data acquisition time and the stability of the light source. The maximum averaging interval 
for irradiance shall correspond to the time interval between I-V data points. 
c) For irradiation exposure LTI shall be verified for the specifications (time period, data 
recording interval for irradiance) given by the supplier. If such information is not available 
LTI shall be related to least 100 irradiance values, with a minimum of one data point per 
hour, taken at equal intervals over the exposure period. 
Determine the LTI value using the minimum and maximum irradiance in accordance with 
formula (2) and Table 3. 
Figure 2 – Evaluation of STI for a long pulse solar simulator 
Copyrighted material licensed to University of Toronto by Clarivate Analytics (US) LLC, subscriptions.techstreet.com, downloaded on 2020-09-26 08:51:03 +0000 by University of Toronto User.
No further reproduction or distribution is permitted.


IEC 60904-9:2020 © IEC 2020 
– 21 – 
Figure 3 – Evaluation of STI for a short pulse solar simulator 
5.4.2 
Solar simulators for irradiance exposure 
For steady-state solar simulators used for irradiation endurance tests only the value of LTI is 
relevant for classification. The following procedure is used to determine the LTI: 
a) Record the irradiance variations in the time period of interest by using a suitable 
irradiance sensor and an appropriate averaging time. If multi-lamp systems are used a 
representative number of locations in the designated test area shall be specified. 
b) Determine maximum irradiance and minimum irradiance from data measured in step a). 
c) Determine the LTI using the data from step b), formula (2). 
d) Apply the calculated value of LTI to determine the classification in Table 3. 